Mcquay model number tonnage

Model MPS. Daikin Maverick II commercial packaged rooftop systems, from 15 to 75 tons, use ozone-friendly R-410A refrigerant and are designed for new, retrofit or replacement applications on one to three-story buildings like offices, schools, libraries, and strip malls. Arriving as a complete packaged solution, Maverick II maximizes your design ...

Mcquay model number tonnage. Daikin RoofPak applied packaged rooftop systems, from 15 to 150 tons, are the ideal solution for your one to eight-story building projects. Available in air-cooled and evaporative-cooled models, they combine the lower installation costs and interior space savings of a roof-mounted system with the operating and maintenance efficiencies of ...

You can determine the size in tons of your Tempstar HVAC system by examining the model number on the data plate at the side of the condenser (outdoor unit). Look for two numbers in the middle of the model number that are divisible by 6 or 12, and represent the nominal BTU of the system in thousands. A ton of air conditioning equals 12,000 BTU ...

NOTE: ARI limit for certification on 60 Hz service is 2,000 tons. McQuay dual compressor chillers with or without VFD are available up to 2,700 tons. The chart below illustrates …Basically all manufacturers encode the size or tonnage of their systems into the model number. Tonnage is a measure of BTU’s in 12,000 BTU increments. For example a 1 ton system would have 12,000 BTU’s. A 2.5 ton system would have 30,000 BTU’s. These are reflected in the model numbers near the middle and often followed by a letter.Find Us. McQuay Air-conditioning Limited (+852) 2893 6261; Unit 901~905, 9/F,Elite Centre, 22 Hung To Road, Kwun Tong, Kowloon,Hong KongPage 83: Medium/High Voltage Starters, 2300V - 7.2Kv. This section contains information on medium voltage, across-the-line and solid state starters as manufactured by Benshaw Inc. for McQuay centrifugal Chillers. Medium voltage starters have similar software (Micro II) and are grouped together in this manual.Nomenclature. ACU Split System Air Conditioners. 1-1/2 to 5 ton. © 2004 McQuay International. IM-800. Installation and Maintenance Manual. IM-800. Group: Unitary. Part … The McQuay company and brand, including their range of air conditioning and chiller units, was acquired by Daikin in 2006 and we and our distributors now provide full support for McQuay spare parts and product information. The McQuay company was originally founded in 1933 in Minneapolis, USA. After combining with Daikin in 2006 and acquiring ... Enfinity console water source heat pumps (WSHP), from 1/2 to 1-1/2 tons, are designed for high-efficiency, individually-zoned comfort control in offices, schools, assisted living facilities, manufacturing buildings, and a variety of commercial applications. Using ozone-friendly R-410A refrigerant, Enfinity's quiet, high performance and ...

One essential piece of information is the model number. This alphanumeric code holds the secret to figuring out the size of your system. ... Model Number Tonnage; 18: 1.5: 24: 2: 30: 2.5: 36: 3: 42: 3.5: 48: 4: 60: 5: This table provides a clear breakdown of the model numbers and their corresponding tonnage values for your Heil air conditioners ...Simply divide the BTUs by 12,000 to calculate the tonnage of your unit. For example, if your air conditioner is 36,000 BTUs, you have a 3-ton unit. Some manufacturers bury tonnage or BTU information in their model numbers. Look for an even, two-digit number between 18 and 60. How old is my heat pump? How do I read my carrier heat pump serial ...Do you know how to make a 3-D model for oxygen? Find out how to make a 3-D model for oxygen in this article from HowStuffWorks. Advertisement One of the most effective and fun ways...A ton of air conditioning equals 12,000 BTU so, for the model number C4H3 60 GKD400, 60 divided by 12 equals 5 tons. Another example is CSH6 48 GKA, which is 4 tons. Here's a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 - 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, and 60 = 5 tons.York HVAC Model Number Name Decoding Guide. YORK HVAC EQUIPMENT NOMENCLATURE GUIDE - DECODE the PRODUCT NUMBER found on the EQUPMENT DATA TAG. CLICK ANYWHERE on THIS PAGE to RETURN to YORK HVAC Information at InspectApedia.com. z Z z a z zoa g z Z 33 00 < z 88 o o z < e a 2 z o. W x.

Today, McQuay possesses more than 13 manufacturing plants occupying some 200,000 square meters on three continents; North America, Europe and Asia together with sales and service offices in 75 countries. With a diligent workforce of over 15,000, McQuay is dedicated to producing the best quality equipment in the air conditioning industry.Look for the 7th and 8th digits, or maybe 8th and 9th digits, of the model number. It will be a number divisible by 6 or 12, and represents the nominal BTU of the system in thousands. A ton of air conditioning equals 12,000 BTU, and 36 divided by 12 equals 3, so the data plate below indicates the system is 3 tons. York/Quantech – Johnson Controls. Our literature library of data sheets, manuals, & engineering specs is constantly growing. If you need finding product literature call us at 214-321-4200. SALES Hunter: 713-851-7576 Jamey: 214-755-8019 . Para Español: 214-321-4200 McQuay Horizontal Water Source Heat Pump - 1/2 to 6 Ton - Free download as PDF File (.pdf), Text File (.txt) or read online for free.1997 McQuay Air Cooled Chiller- 90 Ton. Model ALS090, S/N 57G8140101. (1) Compressor: 130 hp motor, 343 LRA, 208-230 V, 3 phase. (8) Condenser fan motors: 1.5 hp, 5.8 LRA, 208 V, 3 phase. (1) Crankcase heater: 1.7 LRA, 115 V, 1 phase. Requires min 410 amp circuit breaker and 700 amp fuses. Uses 180 lbs. of refrigerant

Floral reflections in st henry ohio.

3-6 Ton DFC Light Commercial 3-5 TON - 13.4 SEER2/11 EER2 3-5 TON - 14 SEER/11.5 EER 6TON - 15.5 IEER/11.2 EER. Our Perfect Package: ... New Daikin 3-6 Ton Direct Drive Model Number Codestring DFC0361D000001S DFC0361DXXXAXAXXXXXXXX DFC0363D0000001S DFC0363DXXXAXAXXXXXXXXRuby: 972-777-6574. Jamey: 214-755-8019. [email protected]. Our Location. Our main service facility is located in Dallas, Texas. We ship anywhere in the United States, Mexico, Canada, South America and Internationally. Surplus Group. 2121 Santa Anna Ave. Suite 100.Daikin offers a wide range of condensing units from 6 to 140 tons with a full range of options to meet efficiency, performance or serviceability requirements. Our model RCS condensing unit meets ASHRAE 90.1 2010 efficiencies, uses scroll compressors for reliability, offers optional condenser fans for quiet operation, and provides low ambient ...Please consult McQuay Sales Representative for specific availability. McQuay WSHP Product Nomenclature WCMS 1009 E Z Product Category W = WSHP Product Identifier See box below Design Series 1 = A Design 2 = B Design 3 = C Design 4 = D Design 5 = E Design Nominal Capacity 007 = 7,000 009 = 9,000 012 = 12,000 015 = 15,000 019 = 19,000 etc ...McQuay Airmatic Air Cooled Chiller 175 Ton, 1995 model,Model ALR175C, S/N 5ZM8178401. Barrel information: year 1994, Model E1610, S/N 52M0003700, 6-1/2 in. outlet on barrel. (4) compressors, 50 hp, 83 rla, 535 lra, 460 volt, 60hz, 3ph. Overall dimensions 7ft. 5 in. x 22 ft. 6 in. x 7 ft.

Allows for leak-resistant section to section joining in the field. Easy-to-remove access panels Allows for easy inspection and cleaning of drain pans; promotes regular inspections. CAT 550-14 • VISION AIR HANDLER 4 www.DaikinApplied.com. The Vision Air Handler Advantage. Daikin RoofPak applied packaged rooftop systems, from 15 to 150 tons, are the ideal solution for your one to eight-story building projects. Available in air-cooled and evaporative-cooled models, they combine the lower installation costs and interior space savings of a roof-mounted system with the operating and maintenance efficiencies of ... 60Hz SEER10 R410A Cooling Only. Notes: The cooling condition: T1 condition: indoor side 27°C (80.6°F) DB, 19°C (60°F) WB, outdoor side 35°C (95°F) DB; The heating condition: indoor side 20°C (68°F) DB, 15°C (44.6°F) WB, outdoor side 7°C (42.8°F) DB. Sound level: measured at a point 1m in front of the unit at a height of 1.3m.Whether you need to make a warranty claim or find replacement parts, there are plenty of reasons why you may need to find the model number for your GE motor. Here are several helpf...This Used MCQUAY 50 Ton Water Cooled Chiller has been inspected and is located in our facility in Bridgeport, Tx. We Buy and We Sell New and Used Chillers, Cooling Towers and Equipment. ... Model Number: WGZ050AW27-ER10; Serial Number: STNU071100075; Year: 2007; 50 Tons Nominal Cooling; 460V/3Ph/60Hz; Refrigerant: R-22; Scroll Compressors;McQuay Air Cooled Water Chiller- 220 Ton. Model ALS220A, S/N 56K8146201. (2) Compressors. Refrigerant: R 22. Overall dimensions: 356 in. L x 84 in. W x 95 in. H. Browse Model Number DX16SA0371, 16 SEER AC UNITARY 3 TON SINGLE STAGE in the Daikin North America LLC catalog including Model Number,Item Name,Description,Nominal Cooling Capacity,Sound Level,Compressor - Rated Load Amps,Compressor - Locked Rotor Amp The Model 3 "is going to blow many, many minds." Tesla hopes to enter the hearts—and driveways—of millions of people around the world with the debut of its first mass-market electr...Tesla delivered a record-breaking 241,300 electric vehicles in the third quarter, blowing past expectations as other U.S. automakers experienced a drop in sales as the result of a ...Find Us. McQuay Air-conditioning Limited (+852) 2893 6261; Unit 901~905, 9/F,Elite Centre, 22 Hung To Road, Kwun Tong, Kowloon,Hong KongFor demanding filtration, Daikin's custom air handler unit provides advanced filtration with HEPA, PCO, gas phase, and low pressure filters. They also help you achieve higher indoor air quality by using ultra-violet lights, stainless steel drain pans, and anti-microbial liner options. 003-169 Unit Sizes. 900 to 129,000 CFM.

1997 McQuay Air Cooled Chiller- 90 Ton. Model ALS090, S/N 57G8140101. (1) Compressor: 130 hp motor, 343 LRA, 208-230 V, 3 phase. (8) Condenser fan motors: 1.5 hp, 5.8 LRA, 208 V, 3 phase. (1) Crankcase heater: 1.7 LRA, 115 V, 1 phase. Requires min 410 amp circuit breaker and 700 amp fuses. Uses 180 lbs. of refrigerant

Model MPS. Maverick® I packaged rooftop systems, from 3 to 25 tons, are designed from the ground up to include the features and benefits that are ideal for offices, schools, libraries, and strip malls. They combine the lower installation costs and interior space savings of a roof-mounted system with the operating and maintenance efficiencies ...Daikin McQuay Path nder Air Cooled Chiller Screw Compressor 2 Circuit Model: AWS Sizes: 280- 350 Vintage: A R134a 50 Hz Replacement Parts List No. 700014200 New 08/09 To nd your McQuay parts distributor, call 1-800-377-2787 or visit www .mcquay. comIn 2009 we added McQuay Water Source Heat Pump units to our product line. We handle Horizontal, Vertical, and Console units up to 72000 BTU. Over 40 years ago McQuay introduced a complete line of water source heat pumps. WSHP units are used in schools, hospitals, office buildings, hotels, and many other applications.consistent with the McQuay rooftop line. Expanded flexibility along with the availability of the state-of-the-art, MicroTech direct digital control (DDC) system on the RDS 800C and 802C makes the RDS unit the ideal selection in rooftop air handlers. Lower installation costs The McQuay RoofPak air handling unit arrives on the job siteModels AGZ-E, AGZ-F, AMZ, EWYQ. Cool your building more efficiently and save money with the Trailblazer air-cooled scroll chiller. The Trailblazer is Daikin Applied's first available unit designed with R32 refrigerant, boasting a 33% reduced footprint and 10% reduced weight. Trailblazer chillers operate in off-design conditions 95% of the ...Aug 10, 2023 · The tonnage of an AC unit can typically be determined from the model number by looking for a number that is divisible by 12. For example, if the model number is ABC12345, and the number 36 appears in the middle of the model number (e.g., ABC36 12345), then the AC unit is likely a 3-ton unit, since 36 is divisible by 12. 48TC UNITS MODEL NUMBER NOMENCLATURE Model Series - WeatherMaker ® TC - Standard Efficiency Unit Heat Type 48 - Gas Heat Packaged Rooftop Cooling Tons (Vertical Airflow) 17 = 15 tons 28 = 25 tons 20 = 17.5 tons 30 = 27.5 tons 24 = 20 tons Heat Options D = Low Gas Heat E = Medium Gas Heat F = High Gas Heat S = Low Heat w/ Stainless Steel ExchangerCommercial water source heat pumps can be applied to geothermal closed-circuit or open-well loops, or on a traditional boiler/tower loop system. These systems offer benefits ranging from low cost installation to the highest energy efficiency available in the market today. SmartSource® DOAS WSHP. 600 to 4,000 CFM. Product Info.Don't compromise the performance of your McQuay HVAC equipment by using generic substitutes. Trust the experts at Air Distributors for Certified McQuay Parts that will keep your equipment running smoothly for years to come. Call us today at 800-866-1210 or fill out the form on our website to get started.

Lowe's pressure washer extension wand.

Body slider skyrim.

Page 1 Centrifugal Compressor Water Chillers THE DISTINCTION SERIES ™ ™ Model WDC, Dual Compressor, 160 to 2700 Tons (560 to 9500 kW) Model WSC ... Impeller from a McQuay single stage 300 ton (1050 kW) compressor; diameter = 6.3 in. (16 cm), weight = 3.0 lb (1.4 kg) Right: One of three impellers from a 300 ton HCFC-123 compressor; …McQuay Air-conditioning Limited offers a wide range of unitary products, including split systems, rooftop units, fan coils, air handling units and water source heat pumps. These products are designed to provide reliable and energy-efficient cooling and heating solutions for various applications. Visit our website to learn more about our unitary products and …FIND A LOCAL REPRESENTATIVE. Daikin Applied Representatives are knowledgeable, experienced engineers. They support you in exploring all HVAC system alternatives — from large central-chilled water plants to geothermal heat pump systems — to help you design and build the optimal HVAC system for your building and your budget.DMAIC Model - The DMAIC model is commonly used in the Six Sigma process. Learn the ins and outs of the DMAIC model and how it applies to business optimization. Advertisement Proce...5 Tons = 60,000 BTU = 3,000 sq. feet (Model: RACCZR060) You can also manually compute the AC size based on the measurement of the area to be cooled. On average you'll need 0.0016 tons of AC per square foot. For instance, your house is 600 square feet. Multiply 600 by 25 BTU, and the product is 15,000.These links wiIl lead to yóu purchase a próduct from another cómpany. Mcquay Chiller Model Numbers Serial Numbers And How Question Posted By Francisco the Building Engineer on May 3, 2011 Refer to the manufacturers website for their HVAC nomenclature of the model number and serial numbers and how those numbers …Catalog 1108- McQuay Efinity Horizontal Water Source Heat Pumps Page 3 of 76. Enfinity Horizontal Ceiling Water Source Heat Pumps Sizes 007-070 (1/2 to 6 Tons) ModelWCCH(StandardRange:55°Fto110°F) Model WCCW(GeothermalRange:30°Fto110°F) McQuay Enfinity Horizontal Ceiling units are designed for use in multiple floor apartments, office ...The cooling and gas heating units with bottom duct connections, model EPGDA, are available in four cooling capacities: 2, 3, 4 and·5 tons. In ad­ dition, the EPGDA units are available with a 1 horsepower belt drive supply fan/motor assembly for higher static pressure applications on 3, 4 and 5 ton, 3-phase units.The Rheem RPKA-049JAZ heat pump is a 4-ton unit. Rheem heat pumps with 048 or 049 in the model number have a nominal cooling capacity of 48,000 British Thermal Units (BTUs) per hou... ….

McQuay Horizontal Water Source Heat Pump - 1/2 to 6 Ton - Free download as PDF File (.pdf), Text File (.txt) or read online for free.View and Download McQuay SWT C Series installation and maintenance manual online. Self-contained Air Conditioning System Vintage Sizes 18 thru 40. SWT C Series air conditioner pdf manual download. Also for: Swt018c, Swt023c, Swt028c, Swt035c, Swt040c.Page 5: Added Serial Number Nomenclature section. Page 6- 8: Added Unit Code Index section. Page 9: Added Coil Section. Page 11: Changed footnote #1 to: "Part numbers ordered per Code Item on original G.O. Contact McQuay Parts with model and serial number information so the needed part(s) can becorrectlyidentified."Browse Model Number DX16SA0371, 16 SEER AC UNITARY 3 TON SINGLE STAGE in the Daikin North America LLC catalog including Model Number,Item Name,Description,Nominal Cooling Capacity,Sound Level,Compressor - Rated Load Amps,Compressor - Locked Rotor AmpUnit consists of two Mcquay- remanufactured screw compressors. Model SAL167RA12DA, S/N 50BR7021-10 & 52BR7058-10. Both compressors are 460 Volts, 3 phase, 60 Hz, LRA- 489, and START- 764. This unit also consists of a Snyder General / Multi- Tube. National Board Number- 19823, STYLE # - 581595AG08, MODEL E1610, S/N 5YC0024300, AND CRN- C4312.6.the last digit in the model number following the "D" vintage designation (i.e. AGS 220DS or AGS 220DM) are designed to meet ASHRAE 90.1 efficiency standard. These units provide the lowest dollar per ton price. Ratings begin on page 18. High Efficiency, designated by an "E" (or "F" with remote evaporator) as the lastTGZ 080A. Operation And Maintenance Manual. Show all McQuay Water Heater manuals. View & download of more than 2218 McQuay PDF user manuals, service manuals, operating guides. Air Conditioner, Chiller user manuals, operating guides & specifications.Model AGZ 026Bthrough AGZ 130B Two-Circuit Chiller (4-Fan Model Illustrated) Model AGZ 010A through AGZ 034A, Single Circuit Chiller Cover Pictures: The upper unit is a Model AGZ 034A, 34 ton chiller. The lower unit is a Model AGZ 130B, 130 ton chiller with the end protective guard removed in order to view the unit interior. “W” Shaped Coil Mcquay model number tonnage, The date of production/manufacture or age of Marley® HVAC equipment can be determined from the serial number located on the data plate. Parent Company: Marley - SPX. Example serial number styles/formats found: Style 1: AQ-10041433-A1 496M., McQUAY CENTRIFUGAL CHILLER - TECHNICAL BREAKDOWN Date saved : June 25, 2007 (CH-1 400T (0.368 kW/ton NPLV)) Page 1 JOB NAME M22282 REP. OFFICE Long Building Technologies JOB DESCRIPTION 1900 16th St SALESMAN RR CUSTOMER MODEL NUMBER ... Enclosure type NEMA 1 Model number VFD028YMA, Below: McQuay rooftop unit model number decoder. Below: Snyder General or McQuay rooftop unit CUR model nomenclature decoder. Below: more Snyder General or McQuay installation or operating manuals. Snyder General McQuay CUR-Series 075-150 ROOFTOP UNIT MANUAL [PDF] (1993) Models CUR075G through CUR 150G, A three-speed control switch with off position and wall plate is furnished for installation by the contractor in a standard 2 x 4-inch junction box. The speed switch can be wired to any three of the four motor taps to provide air delivery in three increments from 100% to 50% of rated airflow. Air discharge., Ruby: 972-777-6574. Jamey: 214-755-8019. [email protected]. Our Location. Our main service facility is located in Dallas, Texas. We ship anywhere in the United States, Mexico, Canada, South America and Internationally. Surplus …, Since 1980s, McQuay and its former name Westinghouse, were distributed by a local Government Registered E&M contracting company and successfully penetrated into the market of public utilities and private sectors. Number of water cooled and air cooled chillers were installed in Government buildings, hospitals, commercial and industry buildings., Model CAH = Custom modular air handler CAC = Custom modular component Nominal unit size (nominal square foot of coil) 107, 124, 141, 160, 169 Daikin air handling unit series Unit cross section C = Standard unit cross section M = Custom size cross section Motor location A = Motor along side of fan housing, burner model number, minimum/maximum input, maximum temperature rise, and minimum CFM. On units that utili ze the tandem scroll compressor design, each compressor includes an individual nameplate along with a nameplate identifying the tandem compressors. On units that utilize the tandem reciprocating design, each, SALES Hunter: 713-851-7576 Jamey: 214-755-8019 . Para Español: 214-321-4200, YORK, We can determine the nominal size of Luxaire furnace system by examining the model number. Tonnage is a measure of BTU's in 12,000 BTU increments. For example a 1 ton system would have 12,000 BTU's. A 2.5 ton system would have 30,000 BTU's. From the Luxaire furnace model number above, with the effeciency rating (AFUE) 80%., technology and quiet operation. Model AGS units utilize a new compressor design utilizing R-134a refrigerant. Superior control is used with the MicroTech II® family of controllers with Open Choices™. They continues McQuay's position of being the only air-cooled screw compressor chiller with superior solid state starters as standard equipment., ner on the main control box door. It includes the unit model number, serial number, unit part number, electrical character-istics, and refrigerant charge. Compressor Nameplate On units with a single compressor on each circuit, the com-pressor will include one compressor nameplate. On units that utilize the tandem compressor design, each, The McQuay RoofPak air handling unit arrives on the job site fully assembled and factory tested ready for start-up. An ... labeled and all wiring is color and number coded. A large, Catalog 206 / Page 5 The available MicroTech controller on the RDS 800C and 802C provides complete temperature control and, if re-, View and Download McQuay ACU018ARAY installation and maintenance manual online. ACU Split System Air Conditioners 1-1/2 to 5 ton. ACU018ARAY air conditioner pdf manual download. Also for: Acu024aray, Acu030aray, Acu036aray, Acu036apay, Acu042aray, Acu049aray, Acu049apay, Acu060aray,..., General Directions: (1) Locate the model number your researching. (2) Hover over each grouping to reveal pertinent info for each part of the model number. (Note: Tonnage, Air Flow, kW, etc. are located within the oval/round shaped buttons). Thank-You For Sharing. T**H1 Unit Nomenclature., We would like to show you a description here but the site won't allow us., Available from 300 to 1200 tons, single compressor centrifugal chillers offer excellent full-load and part-load performance for increased energy savings and an excellent life cycle return on your investment. Using R-134a or R513A refrigerant, these chillers easily integrate with building automation systems, are seismic compliant, quiet and have ..., McQuay Air-conditioning Limited offers a wide range of unitary products, including split systems, rooftop units, fan coils, air handling units and water source heat pumps. These products are designed to provide reliable and energy-efficient cooling and heating solutions for various applications. Visit our website to learn more about our unitary products and …, McQuay Air Conditioning plant with over 450,000 square feet of manufacturing space - located in Auburn, New York Horizontal (Ceiling) Water Source Heat Pumps – Sizes 007-070 (1/2 to 6 Tons) Model CRH (Standard Range: 55°F to 110°F) Model CRW (Extended Range/Geothermal: 25°F to 110°F) More than 40 years ago, McQuay designed the first , The units have automatic control of the condenser fans which should provide adequate head pressure control down to: 50°F (10°C) as standard. 0°F (-17°C) with option (see “Optional Low Ambient Compressor Operation” on page 16) …, Find many great new & used machinery deals and get the best price for 800 Ton, McQuay #PEH126BCBB, package chiller, water cooled, R-134A, Microtech 200 controls, s/n at Surplus Record. Trusted by machinery dealers & buyers for 100 years! go to top. ... Model: PEH126BCBB. Year: 1997., Daikin AC, The McQuay RoofPak air handling unit arrives on the job site fully assembled and factory tested ready for start-up. An ... labeled and all wiring is color and number coded. A …, McQuay International offers a complete range of condensing units from 12 to 120 tons (42 to 420 kW). This manual covers Model ALP 027C through ALP 041C condensing units with capacities from 25 to 40 tons (88 to 140 kW). See Product Manual ALP1-2 for information on Models ALP 012D through ALP 019D,, Cover pictures: Upper unit: Model WSC 087, 500 ton single compressor chiller with factory-mounted starter Lower unit: Model WDC 126, 2000 ton, dual compressor chiller ... Application McQuay Model Cooling, most hours at full load WSC - Single compressor chiller Cooling, most hours at part load WDC - Dual compressor chiller ..., The subbase for the Suite II series hydronic heat model is 8" high with a front air intake grille. Leveling legs are supplied with each subbase that allow for an additional 1" adjustment. The standard subbase requires a minimum of 4-3 /8" from the front edge of the wall sleeve to the finished wall., Mcquay CAC Model AHU Catalog_Vision - Free download as PDF File (.pdf), Text File (.txt) or read online for free., This number can range from 18 to 60. To determine the tonnage of your AC unit, divide this two-digit number by 12. '12' represents 12,000 BTU/hr or one tonnage of cooling capacity. Refer below for the corresponding tonnage based on the number and BTU information: 18 = 1.5 tons. 24 = 2 tons., A ton of air conditioning equals 12,000 BTU, and 24 divided by 12 equals 2, so the data plate below indicates the system is 2 tons. Here's a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 - 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, and 60 = 5 tons. If you are unsure whether you have found the right two ..., Daikin Applied, Browse Model Number DX16SA0371, 16 SEER AC UNITARY 3 TON SINGLE STAGE in the Daikin North America LLC catalog including Model Number,Item Name,Description,Nominal Cooling Capacity,Sound Level,Compressor - Rated Load Amps,Compressor - Locked Rotor Amp, Page 36 3-1/2 x No. of DX rows *DX coil configuration (S = Standard, L = Large) is identified by the 8th digit of the RPS/RDT or RFS model number, found on the unit nameplate. For example, DX = L for unit model …