Masterbuilt 560 control panel not working

Also Read: Masterbuilt 560 Control Panel/Display Not Working – Fix It Now How To Repair Masterbuilt 560 Firebox. Truth be told, your Masterbuilt 560 firebox is better to be replaced than repaired if there is an issue. I have suggested a very good replacement kit with the gasket material above. You can try this out.

Masterbuilt 560 control panel not working. Also Read: Masterbuilt 560 Control Panel/Display Not Working – Fix It Now How To Repair Masterbuilt 560 Firebox. Truth be told, your Masterbuilt 560 firebox is better to be replaced than repaired if there is an issue. I have suggested a very good replacement kit with the gasket material above. You can try this out.

Amazon.com : 9904190036 Controller Compatible with Masterbuilt Gravity Series 560 Digital Charcoal Grill + Smokers, Digital Control Panel (Non-Wifi) for Model: MB20040220, MB20041020 Replacement Part : Patio, Lawn & Garden

#1. Temperature Control Issues. One of the most common problems with the Masterbuilt 560 is temperature control issues. You may find that the temperature won’t …Masterbuilt MB20080220 Gravity Series 560 Digital Charcoal Grill and Smoker Combo Cover, Black ... Set your cooking time and temperature on the digital control panel or using the Masterbuilt app. PRODUCT FEATURES ... My only issue is that I used it in the rain and the digital display does not work as well anymore, so I have …So it’s pretty sure the Masterbuilt smoker beeping issue has been resolved yet and the panel will start working. Note: If your control panel is outdated, then you should better go for replacement. Have a … Grill Comparison | Masterbuilt Gravity Series® 560 vs 1050. Find manuals, parts, cooking tips and videos to help you get the most our of your Masterbuilt® grill, smoker or fryer. If you need more help you can also register your product or open a support ticket. The EarthLink Control Panel is a powerful tool that allows users to manage their online presence with ease. When you first log in to the EarthLink Control Panel, you will be greete...

When it comes to your vehicle’s brake system, you want the best performance possible. One way to ensure that your brakes are working optimally is by upgrading to a splash panel bra...Step 6: Restart Your Masterbuilt Grill and Mobile Phone. I know this step seems obvious, but don’t overlook it. More often than not, restarting your phone resolves the connectivity issue. If Bluetooth or WiFi isn’t working after restarting your mobile device, try turning your Masterbuilt unit off and on.Causes for Masterbuilt Smoker Heating Element Not Working Using A Water Pan While Smoking With Your Masterbuilt Smoker. If you’ve been using a water pan while smoking, the water in the pan may have allowed moisture to corrode the wiring in your Masterbuilt smoker.. The most likely location is the writing close to the water pan, which is the …Control temperature and cooking time with digital control panel or smart device control using Bluetooth, can efficiently and accurately display the internal temperature of the tobacco rack. Easy to install and use:9904190036 Controller contains 1*Digital Control Panel (NOTE: DOES NOT COME WITH ANTENNA).First, you need to find out what’s stopping the display to work fine. So, let’s break down the common causes behind the malfunction of the Masterbuilt 560 display/control panel. Dirty Control Panel. Have you not cleaned your Masterbuilt 560 for a long time?

Oct 19, 2021 · My problems were usually when I would raise the temp to go from smoke to sear and the temp would stall somewhere around 400 °. Haven't has a problem since I started using contact cleaner and manually working the switches for 20-30 secs or so. This Item: Masterbuilt Controller For Gravity Series 560 Digital Charcoal Grill & Smokers: 9904190036-AMP - $49.99. Masterbuilt Meat Probe For Gravity Series Grills: 9004190170 - $9.99. Total Price: $59.98. Add All To Cart. Description Compatible Models Technical Specs. Videos Instructions. Solar charge controllers play a crucial role in optimizing the performance of solar panels by regulating the flow of energy from the panels to the batteries. They ensure that batte...Solution 3: Checking the Control Panel. To check the control panel on your masterbuilt smoker, you’ll need to take a closer look at the wiring and connections. The control panel is responsible for regulating the temperature and cooking time, so it’s important to ensure that it’s functioning properly. Here are some steps to follow:So I opened a ticket with masterbuilt support. It's not uncommon to see messages of frustration regarding connecting the Gravity grills to WiFi. ... The update would initially not download, and the physical controls stopped getting a response. I unplugged the power, plugged it back in, and when I connected that time, the update started ...Closing the vents will reduce the temperature. Clean the smoker: If you notice that your Masterbuilt 560 isn’t heating up properly, it may be due to a buildup of ash and grease. Make sure that you clean the smoker regularly to avoid any issues. Remove the ash from the firebox and clean the grates with a wire brush.

Mi ranchito lowell.

Wait for a few minutes before plugging it back in. Press and hold the power button for 15 seconds to clear the control panel’s memory. Turn on the smoker and set the desired temperature or program. If the control panel was causing the heating issue, resetting it should fix the problem.Digital charcoal grill and smoker with 545 square inches of cooking space. QuickStart™ Automatic Ignition lights your fire starter with the push of a button. Digital control panel to easily set desired cooking temperature for grilling or smoking. Internal charcoal MiniHopper™ holds 5lbs of lump charcoal or 7lbs of briquettes for up to 8 ...9907120027 - Element Kit (1200 Watt) $29.99. 9907160014 - Digital Control Panel Kit. $39.99. ... Genuine Masterbuilt® smoker parts including controllers, handles and heating elements for your Masterbuilt smoker. We also sell Masterbuilt grill parts like handles, grills and grates and Masterbuilt fryer parts including deep fryer replacement cords.Jan 10, 2024 · If you’re still having temperature control issues, consider replacing the smoker’s temperature probe. #2. Ignition Problems. Another common issue with the Masterbuilt 560 is ignition problems. You may find that the smoker won’t light or stay lit. This can be caused by a variety of issues, including a clogged burner tube, a faulty igniter ... Signs of a damaged control panel. Detecting a damaged control panel can be crucial in troubleshooting the err 1 issue in your Masterbuilt smoker. A damaged control panel can be caused by various factors, including exposure to extreme weather conditions, frequent use, and mishandling. The following are signs that your control panel may be …6. Faulty Power Light. When the power light of your Masterbuilt smoker doesn’t turn on, it creates a hindrance in turning on the smoker itself. The probable causes of this problem are the following: Improper plugging of smoker power light into the wall. The controller wire connector and smoker are not connected.

Features of the Gravity Series® 1050 Digital Charcoal Grill + Smoker. Digital charcoal grill and smoker with 1050 square inches of cooking space. Reaches 225˚F in 8 minutes or 700˚F in 15 minutes to use as traditional charcoal grill or charcoal smoker. DigitalFan™ precisely maintains desired cooking temperature during grilling or smoking.Vehicle fuse panels are commonly called fuse blocks. Here’s some information about the purpose of fuse panels and how to tell different automotive fuses apart. Many modern vehicles...Plug your Masterbuilt Smoker into an available outlet and press the “ON/OFF” button to power it on. The green power light will be lit and the display will be on. Press the “Continue” button. Step 2: Again, hold down the SET TEMP button on your Masterbuilt smoker until you hear the long beep. Press the “Continue” button.The digital control panel or Masterbuilt app will ... work? Account. Login · Cart. Masterbuilt © 2024. All ... not sell my personal information. Also of Interest.Netflix is working on a feature that would let users utilize iPhones to control games on the TV. Netflix is working on a new feature that could bring its mobile games to the TV. Ba...... Not Compatible with Gravity Series® 560 ** ... control panel doing all the work of maintaining temp. ... working from home due to the corona virus and we were ... Replacement Digital Control Panel for Masterbuilt Gravity Series 560/800/1050 . The Non-WIFI controller supports not only Masterbuilt Gravity Series 560,but also Masterbuilt Gravity Series 800 & 1050 models. Because it adds BOOSTING mode,On Model 800 and 1050 you will find it takes a little bit more time to reach the target temperature. 9904190036 Controller Compatible with Masterbuilt Gravity Series 560 Digital Charcoal Grill + Smokers, Digital Control Panel (Non-Wifi) for Model: MB20040220, MB20041020 Replacement Part 4.3 out of 5 stars 284Amazon.com: Digital Control Panel Replacement Part 9907190002 for Masterbuilt Electric Smoker, Top Digital Controller Compatible with Masterbuilt MB20042218, ... Simply plug this smoker in, set the digital controls, and it does the work! Kit Includes: Control Panel x 1 ; Screws x 2 ; Product Manual x 1 ;

If your Masterbuilt 560 charcoal smoker is plugged in properly and still the fan doesn’t get power, the problem is either in the circuit breaker or fan motor. Check the electrical panel if there’s any blown fuse or tripped circuit breaker. In that case, you need to replace the fuse and then reset the circuit breaker.

Control Panel Not Working. If you find the Masterbuilt 1050 control panel not working, ... App Does Not Working. Masterbuilt gravity series digital charcoal smokers are controlled through the Masterbuilt app. But sometimes the app suddenly crashes due to a poor internet connection, an inappropriate phone model, or an outdated …This is instructions on how to replace a Masterbuilt Model # MB20077618 Electric Smoker Control Panel replacement. This was my first time replacing this or ...Dec 7, 2023 · Why is my Masterbuilt Gravity Series smoker fan not working? 1. The first step is to reset the controller. Unplug your smoker for 5 minutes and then plug it back in to see if the issue resolves. 2. Inspect control panel and wiring for damage or loose connections. Replace or reconnect loose or frayed wires for proper fan operation. Control Panel Support Kit for 30 inch electric smokers. Part Number: 9907090024. Fits Models: 20070210, 20070410, 20070610, 20070612, 20070712, 20070812, 20071012, 20074316, 20074416, 20074516, 20074616, 20075517, 20070410R, 20070610R, 20070610SD, 20070712R, MB20070210, MB21071012, MB25075517 ... For the …Jan 10, 2024 · If you’re still having temperature control issues, consider replacing the smoker’s temperature probe. #2. Ignition Problems. Another common issue with the Masterbuilt 560 is ignition problems. You may find that the smoker won’t light or stay lit. This can be caused by a variety of issues, including a clogged burner tube, a faulty igniter ... 1. Charcoal Pieces Get Stuck. 2. Cabinet Temperature Reached The Set Temperature. 3. Ash Door Open. 4. Controller Issue. 5. Open Hopper Lid. 6. Overheated …Tighten screws beneath manifold. Instal the antenna by screwing it onto the back of the panel. Then, turn the top portion of the antenna as shown. Page 22 Assembly Instal top screws (A) halfway into grill side wall. Place shelf over screw heads, add lower screws (A), then tighten screws.When your Masterbuilt 1050 control panel is not working, one common issue could be related to the power supply. A faulty or loosely connected power cord can cause insufficient power to reach the control panel, preventing it from functioning properly. Additionally, problems with the outlet itself, such as a blown fuse or tripped circuit breaker ...Gravity Series 560. In a nutshell: Enormous grill area cooks up to 21 burgers at once. Control temperature and cooking time with the app or digital controls. Reaches 110°C in 7 minutes or 370°C in 13 minutes. Built-in temperature gauge and meat probe thermometer.Solar energy is becoming increasingly popular as a renewable and sustainable source of power. As more people are considering installing solar panels on their homes or businesses, t...

K nails williamsburg va.

681 albany ave.

Jun 9, 2023 · Make sure the smoker is unplugged and then remove the igniter from the smoker. Check the wires leading to the igniter for any signs of damage or wear. If the wires look good, you can test the igniter with a multimeter to see if it’s working properly. If the igniter is faulty, you’ll need to replace it. Check if the wood chip tray or charcoal holder is positioned properly and securely in the smoker. Ensure it is not obstructing the air vents. If necessary, adjust the placement of the wood chips or charcoal to ensure adequate oxygen flow. Also Read: Masterbuilt 560 Fan Not Working or Won’t Turn On – How To Fix?Your wire connectors are different colors. Please refer to this diagram. This document will help you identify if your Digital Charcoal Smoker is wired correctly. Use this document for any of the following concerns: controller restarts immediately after you set the temperature, controller is reading the wrong temperature, controller does not ...Fix Masterbuilt Smoker Control Panel Won't Stay On Clicks Masterbuilt Electric Smoker http://amzn.to/2DzeeRq trouble shooting smoker control panel Masterb...Features of the Gravity Series® 1050 Digital Charcoal Grill + Smoker. Digital charcoal grill and smoker with 1050 square inches of cooking space. Reaches 225˚F in 8 minutes or 700˚F in 15 minutes to use as traditional charcoal grill or charcoal smoker. DigitalFan™ precisely maintains desired cooking temperature during grilling or smoking.Masterbuilt MB20080220 Gravity Series 560 Digital Charcoal Grill and Smoker Combo Cover, Black ... Set your cooking time and temperature on the digital control panel or using the Masterbuilt app. PRODUCT FEATURES ... My only issue is that I used it in the rain and the digital display does not work as well anymore, so I have …If you’re still having temperature control issues, consider replacing the smoker’s temperature probe. #2. Ignition Problems. Another common issue with the Masterbuilt 560 is ignition problems. You may find that the smoker won’t light or stay lit. This can be caused by a variety of issues, including a clogged burner tube, a faulty igniter ...Jan 12, 2022 · 1. Charcoal Pieces Get Stuck. Your Masterbuilt 560 fan will not come up if the charcoal pieces get stuck in it. If it gets stuck in the fan, it will fail to run. The reasons for this trouble are the following: Shutdown slides remain in the fan. Fully open ash door and hopper lid. Empty charcoal. Blocked ash gate. Also Read: Masterbuilt 560 Control Panel/Display Not Working – Fix It Now How To Repair Masterbuilt 560 Firebox. Truth be told, your Masterbuilt 560 firebox is better to be replaced than repaired if there is an issue. I have suggested a very good replacement kit with the gasket material above. You can try this out.23. 10. Jul 20, 2007. #1. Hello all, I have a question about a Masterbuilt Electric smoker. It has been used only about 15 times, and last week, while attempting to smoke a chicken, everything shut off. The digital timer and temp on top does not do anything and the heating element does not come on. I am figuring that the element is bad, and ...To reach our Customer Support team, you will want to start by making sure that your product is registered via our Product Registration form.. Once your product is registered, you will want to then fill out a Contact Us form, which allows you to outline what you need Customer Support's assistance for and open a case within our system.Please note that response … ….

Amazon.com : Digital Control Panel,9904190036 Controller Compatible with Masterbuilt Gravity Series 560/800/1050 Masterbuilt Control Panel for MB20040220/MB20041020 Electric Smoker Grill Replacement Part(NOT SUPPORT WIFI) : Patio, Lawn & GardenThe Masterbuilt Gravity Series 560 is an impressive BBQ more akin to an outdoor oven than a traditional BBQ. It features a fan-controlled temperature system for stable temps, a gravity-fed hopper for up to 15 hours of use and smartphone connectivity to keep an eye on your meat during longer cooks. It’s expensive, but for some, it’ll be the ...Control Panel and Hose/Valve/Regulator Kit for 40-inch ThemoTemp smokers. Part Number. 9905170015. Fits Models. MB20051316, MB20050418. See full description. Control Panel and Hose/Valve/Regulator Kit for 40-inch ThemoTemp smokers. Part Number. 9905170015.Solution 3: Checking the Control Panel. To check the control panel on your masterbuilt smoker, you’ll need to take a closer look at the wiring and connections. The control panel is responsible for regulating the temperature and cooking time, so it’s important to ensure that it’s functioning properly. Here are some steps to follow:MB 560 would start up just fine and in the middle of a cook the fan would turn off. MB sent me a new controller and temperature probe. Same problem. Switches and fan last electrical items, fan working fine. Read lots of threads about bypassing the switches. Didn't want to do that or take apart.Clear recently viewed. $34.99. SKU. Upgrade your Masterbuilt smoker with the Masterbuilt Digital Control Panel Kit. This kit is compatible with the Masterbuilt 20070311, 20070411, and 20072614 models, and is designed to replace the existing control panel with a digital version. The digital control panel offers a range of benefits over the ...With the Gravity Series 560 Digital Charcoal Grill + Smoker by Master built, you can smoke, grill, sear, bake, roast and so much more. Set the temperature on the digital control panel or your smart device and the Digital …Add the. Masterbuilt Lump Charcoal Bundle - 2 Pack and Fire Starters. $44.99. Total: $59.99. Controller Assembly Kit for Gravity Series® 560 Digital Charcoal Grill + Smokers. Part Number. 9904190036. Fits Models. MB20040220, MB20041020. Simply fill the GravityFed™ vertical charcoal hopper with charcoal, set your cooking temperature on the digital control board or on your smart device using the Masterbuilt app, and let Gravity do the work. Additionally, the Gravity Series 800 includes a flat-top griddle insert to sear and sauté breakfast, burgers, fajitas and more. Masterbuilt 560 control panel not working, The control panel features a “Safety Switch” that must be mounted properly on the mounting bracket of the outer shell for the unit to power on. The power light will illuminate when the control panel is mounted correctly. You may need to reset your fryer. Resetting the Fryer - Video: How to Reset Your Fryer 1. Allow the unit to cool: 2 hours ..., Masterbuilt MB20080220 Gravity Series 560 Digital Charcoal Grill and Smoker Combo Cover, Black ... Set your cooking time and temperature on the digital control panel or using the Masterbuilt app. PRODUCT FEATURES ... My only issue is that I used it in the rain and the digital display does not work as well anymore, so I have …, The second most straightforward answer to a Masterbuilt smoker, not heating, is an unplugged power cord if your socket is on. Check the power cord to ensure you inserted it correctly into the socket. If it is, then the problem could be a breakage. Inspect the entire power cord, particularly at the point it connects to your Masterbuilt smoker., Problem 1: Controller Not Turning On. The power may be turned off if your masterbuilt isn’t working. There could be many reasons. But the main cause behind your smoker not …, Attempted to turn it on and met with some of the 7-segment display not lighting up at all or having strange dimming. The app was unable to connect until I removed it and reset it, but that didn’t help with the display. Even in the shade the 7 segment display isn’t behaving properly. For a $600+ grill, I feel like the display shouldn’t ... , Gravity Series 560 Digital Charcoal BBQ + Smoker. £649.00. Model: MB20041020. With the Gravity Series 560 Digital Charcoal BBQ + Smoker by Masterbuilt, you can smoke, grill, sear, bake, roast and so much more. Set the temperature on the digital control panel or your smart device and the DigitalFan™ maintains the desired cooking temperature., Shut down the grill following the SHUTDOWN instructions. Allow the grill to cool COMPLETELY. Using a napkin or cloth, rub a light coat of cooking oil on smoke + sear grates, warming/smoking racks, charcoal grate, and the inside of the grill lid and body. Repeat steps 3–6 at 350°F. Frequent seasoning prevents rusting., Features of the Gravity Series® 1050 Digital Charcoal Grill + Smoker. Digital charcoal grill and smoker with 1050 square inches of cooking space. Reaches 225˚F in 8 minutes or 700˚F in 15 minutes to use as traditional charcoal grill or charcoal smoker. DigitalFan™ precisely maintains desired cooking temperature during grilling or smoking., Mar 3, 2023 · You can start fixing the issue by resetting the control panel of the Masterbuilt Smoker. All you have to do is push and hold the clear button for five seconds. Then, release the button and see if it has been reset. The method is ideal if the display is faulty and it is a technical issue. , Masterbuilt’s 40-inch Digital Charcoal Smoker marries technology, convenience, and affordability without sacrificing authentic charcoal and wood flavor. With a high-capacity vertical orientation, superior temperature control, and hands-off ease of use, it offers a lot of conveniences and genuine smoke flavor for your dollar., Next, check the Masterbuilt app to see if your smoker has the latest firmware update, which could fix potential software-related problems. Step 2: Check the Control Panel and Wiring. Inspect the control panel for any visible damage or loose connections. Similarly, examine the wiring connecting the fan to the controller., The control panel is an essential component of your computer that allows you to manage and customize various settings. Whether you are a novice user or an experienced one, understa..., 9904190036 Controller Compatible with Masterbuilt Gravity Series 560 Digital Charcoal Grill + Smokers, Digital Control Panel (Non-Wifi) for Model: MB20040220, MB20041020 Replacement Part 4.3 out of 5 stars 284, Option 2. Mix wood chunks in the hopper with charcoal. NOTE: Never use more than 1 1/2 lbs. of wood chunks throughout the hopper. The following steps will get your charcoal grill setup for smoking: Create a 2-zone fire in your charcoal tray or basket by arranging coals on one side of the tray or basket and keeping the other side empty., To repair an oven control panel, remove the control board from the oven, tighten the panel to the board with a screwdriver, then replace and the panel. If the error persists, repla..., The Masterbuilt warranty does not cover rust. Masterbuilt requires proof of purchase for warranty claim, such as a receipt. EUROPEAN RESIDENTS ONLY: Masterbuilt warrants all of its products to be free from defects in material and workmanship under proper assembly, normal use and recommended care for 2 years from the date of original retail ..., Jun 6, 2020 · Masterbuilt Gravity 560; Masterbuilt Digital Charcoal Cabinet; Weber 22" Original Kettle Premium (copper) Weber 26" Original Kettle Premium (light blue) Weber Jumbo Joe Gold (18.5") Weber Smokey Joe Silver (14.5") Brinkmann cabinet charcoal smoker (repurposed) Thermometers. SnS 500 4-probe wireless (3) Maverick XR-50 4-probe Wireless Thermometers , Fixing the Control Panel. When troubleshooting issues with your smoker, one common fix is repairing the control panel. A faulty control panel can cause the temperature to fluctuate or not reach the desired temperature, which can be frustrating. Before attempting to fix the control panel, make sure the smoker is unplugged and cool to the touch., From The Manufacturer. With the Gravity Series 560 Digital Charcoal Grill plus Smoker by Masterbuilt, you can smoke, grill, sear, bake, roast and so much more. Set the temperature on the digital control panel or your smart device and the Digital Fan maintains the desired cooking temperature. The Gravity Fed charcoal hopper holds over 12-hours ..., The second most straightforward answer to a Masterbuilt smoker, not heating, is an unplugged power cord if your socket is on. Check the power cord to ensure you inserted it correctly into the socket. If it is, then the problem could be a breakage. Inspect the entire power cord, particularly at the point it connects to your Masterbuilt smoker., 9907170133 - Digital Control Panel Kit. $29.99. Digital Control Panel Kit (4 Pin) for electric smokers. Part Number. 9907170133. Fits Models. MB20071418, MB21071218, MB21072319, MB21072719, 20071218, 20071814. See full description. Digital Control Panel Kit (4 Pin) for electric smokers. , But when the power cord goes out or the controller gets fried, or the fan stops working, you will be without a grill for however long it takes Masterbuilt to ..., This isn't just any control panel; it's the heart of control efficiency. Easy to navigate and adjust, it lets you manage your cooking without fuss. The intuitive design means less time guessing and more time grilling. The Masterbuilt 560 excels in fuel consumption, making it cost-effective and eco-friendly., When your Masterbuilt 1050 control panel is not working, one common issue could be related to the power supply. A faulty or loosely connected power cord can cause insufficient power to reach the control panel, preventing it from functioning properly. Additionally, problems with the outlet itself, such as a blown fuse or tripped circuit breaker ... , Maintenance Tips. Common Issues with the Control Panel. If you’re experiencing issues with your Masterbuilt smoker’s digital control panel, there are a few common problems that could be causing the trouble. One issue you might encounter is error messages, which can be caused by a variety of factors., Apr 7, 2020 · Fix Masterbuilt Smoker Control Panel Won't Stay On Clicks Masterbuilt Electric Smoker http://amzn.to/2DzeeRq trouble shooting smoker control panel Masterb... , From The Manufacturer. With the Gravity Series 560 Digital Charcoal Grill plus Smoker by Masterbuilt, you can smoke, grill, sear, bake, roast and so much more. Set the temperature on the digital control panel or your smart device and the Digital Fan maintains the desired cooking temperature. The Gravity Fed charcoal hopper holds over 12-hours ... , Digital Control Panel Kit (4 Pin) for electric smokers. Part Number: 9907170133. Fits Models MB20071418, MB21071218, MB21072319, MB21072719, 20071218, 20071814, 20071914. Masterbuilt makes innovative digital charcoal grills, griddles, electric smokers, propane smokers, combination grill & smokers, fryers and more. For the backyard griller …, If you are a horse owner or an equestrian enthusiast, you understand the importance of having a well-designed and functional round yard. A round yard provides a safe and controlled..., If you are a horse owner or an equestrian enthusiast, you understand the importance of having a well-designed and functional round yard. A round yard provides a safe and controlled..., Maintain the fan set temperature to restart it again. 3. Ash Door Open. Open ash door is another cause that may stop the easy operation of the Masterbuilt 560 fan. The other reasons responsible for the fan not working, are the following: Less engaged fan switches hinder the fan’s normal operation. Irregular running of fan., 1. Reset the control panel: Begin fixing the issue by resetting the control panel of the Masterbuilt Smoker. Hold down the clear button for five seconds, then release it to see if the panel has been reset. This method is effective if there is a technical issue with the display. 2., A: There can be several reasons why the fan on your Masterbuilt Gravity Series 560 smoker is not working. It could be due to a power issue, a blockage in the fan blades, a faulty fan motor, or a malfunctioning control panel. Troubleshooting the problem will help identify the specific cause and allow you to fix it.