These valves have a removable 100 mesh strainer as a standard feature. These valves are designed for small refrigeration systems such as refrigerated cases, coolers, and freezers where space is limited and an external adjustment is desired. Overall height: 3.76" Element size: 43; Capillary length: 30" Connection: ODF inlet x ODF outlet» SPORLAN THERMOSTATIC EXPANSION VALVE Sporlan thermostatic expansion valves are designed for use on Air Conditioning and Refrigeration Why and How to Adjust a TXV/TEV 2018-07-23 ACHR News Find many great new used options and get the best deals for Sporlan Thermal Expansion Valve Kit for Y1158-CBBIVE-5-GA 1TV0703 1TV0703A at the bestSporlan Type ADR discharge bypass valves limit the minimum evaporating pressure during periods of low load to prevent coil icing and avoid operating the compressor at suction pressures below its operating range.Identification Tag, Cartridge, Yellow, Qty. 5. Identification Tag, Cartridge, Yellow, Qty.4. Kit Contains- 1 Element Gasket, 2 Bushing Gaskets, 1 Bottom Cap Gasket, 1 Seal Cap Gasket, 1 Pushrod, 1 Pushrod Gauge, 1 Piston Assembly, 1 Seat Refinishing Tool with Grit Cloth, 1 Set of Instructions. ( For use with V Valves dated B65 or later and for W.Sporlan's OVE-40CP100 Thermostatic Expansion Valve is ideal for both residential and commercial HVACR applications. With a nominal capacity of 40 tons, it is designed with a 1-1/8 ODF inlet, a 1-3/8 ODF outlet, and is rated for use with R22 or R407C refrigerants. This expansion valve is built for durability, with an equalization type of ...

Re: Adjusting Sporlan TXV for SH. Adjusting the superheat setting may only serve to mask your problem and should not be undertaken lightly. You should really be sure of your the air volume across the evap and the load its generating. Does the unit have a sight glass, whats the liquid temp, is the TXV bulb secure and placed properly.This Parker Sporlan webinar will discuss Thermostatic Expansion Valves as part of the RSES training presentation. Learn everything you need to know about the...According to the St. Bernardine Medical Center, a contractual adjustment is part of the bill that a hospital has agreed not to charge a patient because of billing agreements with t...Identification Tag, Cartridge, Yellow, Qty. 5. Identification Tag, Cartridge, Yellow, Qty.4. Kit Contains- 1 Element Gasket, 2 Bushing Gaskets, 1 Bottom Cap Gasket, 1 Seal Cap Gasket, 1 Pushrod, 1 Pushrod Gauge, 1 Piston Assembly, 1 Seat Refinishing Tool with Grit Cloth, 1 Set of Instructions. ( For use with V Valves dated B65 or later and for W.The reception of Hydraulic Schematics. In to sporlan references available thermal images are standard used to determine the txv is the glass by danfoss provides climate technologies, press the outside air. Heat pumps manual and danfoss for air conditioning. High efficiency of sporlan to survey the txv.An actuarial adjustment is a factor used to adjust your pension payments from a retirement plan if you decide to begin receiving your payments before or after the plan's normal ret...EFS1C. Expansion valve, standard port, R404A family, internal equalizer, 1 ton, 3/8" ODF inlet x 1/2" ODF outlet, C charge (medium temp) Connection Size Inlet (In.): Connection Size Outlet (In.): Overall Height (In.): WARNING: This product can expose you to chemicals including Lead, which are known to the State of California to cause cancer and ...Identification Tag, Cartridge, Yellow, Qty. 5. Identification Tag, Cartridge, Yellow, Qty.4. Kit Contains- 1 Element Gasket, 2 Bushing Gaskets, 1 Bottom Cap Gasket, 1 Seal Cap Gasket, 1 Pushrod, 1 Pushrod Gauge, 1 Piston Assembly, 1 Seat Refinishing Tool with Grit Cloth, 1 Set of Instructions. ( For use with V Valves dated B65 or later and for W.

In this video I swap out a power head on a TXV without recovering the refrigerant. #airconditioner #hvaclife #hvactechnician #hvacguy #acrepair #hvac #hvacin...Sporlan type S valve is a brass bar body, externally adjustable valve with ODF solder connections. The thermostatic element is replaceable and the inlet connection has a permanent 12 mesh strainer. This valve is designed for both air conditioning and refrigeration applications. Capillary length: 5' Connection: ODF inlet x ODF outletSporlan Type P valve is a brass bar body, externally adjustable valve available with ODF solder connections. The thermostatic element is replaceable, and the valve has a permanent 12 mesh strainer. This valve provides smooth and accurate regulation of air conditioning and heat pump applications.Thermostatic Expansion Valve - Sporlan - Type BQ. SBQE BODY 3X4X2 ODF. SBQE BODY 3X4X2 ODF. Thermostatic Expansion Valve - Sporlan - Type BQ. SBQE BODY 3X4X2 ODF. SBQE BODY 3X4X2 ODF ... Sporlan Division 206 Lange Drive Washington, MO 63090 USA. Phone:+1 (636) 239-1111. Technical Specifications. Maximum Pressure (psi):Thermostatic expansion valve type T 2 and TE 2: English: Multiple : 07 Sep, 2023: 1.6 MB .pdf: Software. The truth is Cool(selector®2) Coolselector®2 features unbiased calculations for the selection of refrigeration and air conditioning components based on the user's requirements or based on standard operating conditions. ...The following is a selection of Sporlan references available for download. All information is in portable document format (.pdf). ... Thermostatic Expansion Valve Selection Chart for L.R.C. Coil Company: Bulletin 500-10-M-BP: Balanced Port Thermostatic Expansion Valve Selection Chart for Chandler:

Alex eubank greek god program pdf.

Why TXVs hunt There are several common reasons the service tech should consider when determining why a TXV hunts. Oversized valve: The expansion valve may be oversized for the application or operating condition of the system. Valve capacity significantly exceeds the requirements of the system and when the valve attempts to adjust to system load, it overcompensates because it is oversized.Válvula de expansión termostática - Sporlan - Tipo O. Las válvulas de expansión termostática O de Parker Sporlan están diseñadas para unidades de aire acondicionado y refrigeración. Regulan el flujo de refrigerante al mantener un recalentamiento casi constante en la salida del evaporador.TXV superheat adjustment If these issues cannot be corrected by any other way, adjust the valve’s superheat. Note: adjusting the superheat should only be done after all other corrective measures have been taken. When adjusting the superheat (as seen in Figure 5), verify the rate of change per turn of the superheat spindle for the specific TXVEBSJE7C - SPORLAN 7TON R134A BAL PORT THERMOSTATIC EXPANSION VALVE 5/8X7/8 163505 Toggle navigation. Menu. URI Events; Branch Locator; Sign In | Register; Products. Products ... SPORLAN BAL PORT THERMOSTATIC EXPANSION VALVE 163706 . View Inventory. Add to Cart. Nearby Stock. Add to Job List Compare.RCZE4GA. $ 419.20 View Contractor Pricing. View Inventory. Expansion valve, standard port, R410A family, external equalizer, 4 tons, 1/2" ODF inlet x 1/2" ODF outlet. Quantity.

TXV superheat adjustment If these issues cannot be corrected by any other way, adjust the valve’s superheat. Note: adjusting the superheat should only be done after all other corrective measures have been taken. When adjusting the superheat (as seen in Figure 5), verify the rate of change per turn of the superheat spindle for the specific TXVSporlan Division | Parker NA. 840599. 840599. Your session is about to timeout due to inactivity. Click OK to extend your time for an additional 600 minutes. OK.6. Select the Sporlan Selective Thermostatic Charge. Select the charge according to the design evaporating tem-perature from the Table on page 3. Refer to Bulletin 10-9 for a complete discussion of the available Sporlan Selective Thermostatic Charges. Selection Example – Refrigerant 22 Application: medium temperature refrigerationFirst, measure the superheat right at the evaporator outlet in the same general location as the TXV bulb and equalizer. In most cases, the superheat at that point should be 5-10 degrees, but refer to the manufacturer's specs when in doubt. In some cases, you will not have a pressure port at the evaporator, so you must rely on a pressure reading ...If a display is too large and is causing some of the objects on the screen to be unseen, adjust the display size using the screen resizing buttons present on the monitor. Another o...My 'Druckenmiller' Investing Game Plan: 3 Ways of Adjusting to the New Reality In my Friday column, I highlighted several of famed billionaire Stanley Druckenmiller's curre...To reduce the superheat, turn the adjusting stem COUNTER-CLOCKWISE.Toincreasethesuperheat,turntheadjustingstem Should a Sporlan thermostatic expansion valve (TEV) be adjusted after installation? 52° F C O N V E R T E D T O T E M P . OBTAIN SUCTION PRESSURE . . . 69 PSIG (at bulb) 52 ° 40° 12 ° …In this video I go over Sporlan txv selection for refrigeration applications.This Parker Sporlan webinar will discuss Thermostatic Expansion Valves as part of the RSES training presentation. Learn everything you need to know about the...

When to Replace Expansion Valve: 3 Telltale Signs. Pressure Control and Expansion Valve: A Complete Guide. TXV vs Expansion Valve: A Comprehensive Comparison. Adjusting Superheat on TXV: In 6 Simple Steps. Sporlan TXV Superheat Adjustment: Your Step-by-Step Guide

Warning there is audio issues with this video I was unable to correct. This video we take a deeper look at TXV TEV If your new to TXV TEV start with HVAC 06...1.TYPE VALVE -Sporlan thermostatic expansion valves are available in three body styles — SAE flare, ODF sol-der, or flange. The first letter or letters stamped on the valve body and shown on the label designates the valve type. Valve types are listed below. 2.REFRIGERANT -Sporlanvalves are available for use with most popular refrigerants.ask your sporlan factory rep, they have the tool for the packing nut and adjustment stem for txv. Reply . 09-26-2004, 02:14 AM #9. smilies. View Profile View Forum Posts Visit Homepage View Forum Threads Professional Member ... From what I have been told the Sporlan tool is for TXV gland nuts. Aircraft Mechanical Accessories Technician.Page 2 / BULLETIN 90-21. When adjusting both evaporator pressure regulators and ther-mostatic expansion valves, the following procedure is recom-mended: With the expansion valve at the Sporlan factory setting or at a manufacturer's predetermined set point, and under the actual minimum load condition, the evaporator pressure regulator should ...How to adjust a sporlan txv valve As we discussed in an earlier podcast, a TXV is designed to maintain a specified and constant superheat at the evaporator coil outlet. It does this through a balance of forces between the bulb pressure (opening force), equalizer pressure (closing force), and spring pressure (closing force).The Sporlan TEVs designed for R-410A have replaceable thermostatic elements with a locknut ring stronger than normally used with common refrigerants such as R-22 or R-134a. This feature makes the thermostatic element capable of withstanding higher pressures. Replaceable thermostatic elements are designated by “KT-45-” plus the charge.Aug 31, 2017 · TXV Selector Tool Emerson is pleased to announce the launch of the TXV Selection Tool. This online selection tool allows users to enter their HVACR system characteristics such as refrigerant type, temperatures, pressure drop and capacity, and then selects the best Emerson thermal expansion valves for the application. The Type HX Thermostatic Expansion Valve is designed for use on residential air conditioning and heat pump systems. The valve is available with an integral check valve to bypass refrigerant flow around the expansion device in reverse direction. Sporlan HX and Parker H Valves share the same internal components and feature similar thermostatic ... a Sporlan TEV is close to center stem. Count the total number of turns from front seat to back seat, then front seat the adjustment stem 50% of the total turns counted. Turn the …

Eric bieniemy wife.

Amazon venmo dollar5.

Keeping your brakes working properly is an important part of vehicle maintenance. If your vehicle has drum brakes, you need to adjust them periodically to prevent them from draggin...Evaporator Pressure Regulation. Sporlan Evaporator designed to provide Pressure an economical Regulating valves (EPRs) are means of accurately maintaining varying evaporator evaporator loads. pressure The primary and function temperature of an under EPR is to prevent the evaporator pressure predetermined value temperature is or setting.Pressure Adjustment Control Type: 0-90 psi Adjustment Range; Safety Warning. Safety Warning. FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized ...Sporlan 180918 - KT-85-ZGA TXV Powerhead Element w/ 5' Capillary- Sporlan KT-85-ZGA TXV Powerhead Element Specifications Thermostatic Charge: GA Application: Air Conditioning Capillary Length (inch): 5' Refrigerant Type: R-410A Element Type: 85 Free shipping on orders over $99 Your Zip: 23917 ...Step 1: Locating the TXV. Step 2: Consulting the Manufacturer’s Guidelines. Step 3: Measuring the Current Superheat Value. Step 4: Adjusting the TXV Valve. Step 5: Re …Description. The Series Q and BQ are replaceable cartridge style thermostatic expansion valves, available in both conventional (Type Q) and balanced port (Type BQ) configurations. These valves can be supplied as a complete valve or as three component parts, body, cartridge, and thermostatic element. They are designed for small refrigeration ...In this video we will cover Balanced Port TXV Download the Airefco App: http://bit.ly/airefco-app And make sure to follow us on socials: https://smarturl.i...Study with Quizlet and memorize flashcards containing terms like Can you use a pocket thermometer to calculate superheat? Why or why not?, How is the factory setting of the superheat adjustment determined on a Sporlan expansion valve?, If the compressor is 60 feet from the evaporator, can you use the suction pressure at the compressor valve to calculate evaporator superheat?Bulletin 210-40-4 - Sporlan Field Conversion of the Thermostatic Expansion Valves with Replaceable Thermostatic Elements: Bulletin 210-60 - Sporlan Thermostatic Expansion Valves Identification: SD-14 - Sporlan Thermostatic Expansion Valves Installation, Field Service, and Assembly: SD-289 - Sporlan TEV Installation and InstructionsUse this bulletin to cross reference a standard Sporlan valve for replacement with a Sporlan Balanced Port (Type BQ) valve in four easy steps: 1. Identify the valve to be replaced. The valve's body type, nominal capacity, and thermostatic charge can be determined by inspecting the valve. See the example below for a breakdown of a valve's ….

The cap located at the bottom can be removed. This will expose a 1/4" square valve stem (like a king valve stem) Rotating clockwise will increase the spring tenstion and increase the superheat. All adjustments should be 1/4 turns at a time with a few minutes between adjustments. Set the valve for 10-12 degrees superheat.Sporlan's OVE-40CP100 Thermostatic Expansion Valve is ideal for both residential and commercial HVACR applications. With a nominal capacity of 40 tons, it is designed with a 1-1/8 ODF inlet, a 1-3/8 ODF outlet, and is rated for use with R22 or R407C refrigerants. This expansion valve is built for durability, with an equalization type of ...Sporlan Division Products can and do fail without warning for many rea-sons. Design all systems and equipment in a fail­safe mode, so that fail­ ure of these products and related accessories will not endanger persons or property. Pressure Rating: The maximum internal pressure of the Y1037, Y1210 and Y1244 valves is 500 psig (34 bar).This is the operational opening force in the the valve. A pressure limiting charge (CP or ZP) has a very limited amount of liquid in the bulb, and at some point all that liquid will boil into a vapor. Once that occurs, further increasing the bulb temperature doesn't result in an increase in the bulb pressure. The TXV cannot be adjusted open or closed, it is a modulating valve. Turning the adjustment stem clockwise will only increase spring pressure causing a higher superheat. Turning the adjustment stem counterclockwise will decrease spring pressure reducing superheat. When an operating refrigeration system stops working, the TXV may have lost its ... My 'Druckenmiller' Investing Game Plan: 3 Ways of Adjusting to the New Reality In my Friday column, I highlighted several of famed billionaire Stanley Druckenmiller's curre...When adjusting both evaporator pressure regulating valves and thermostatic expansion valves, the following procedure is recommended. With the expansion valve at the Sporlan factory setting, or at a manufacturer's predetermined setpoint, and under the actual minimum load condition, the evaporator pressureBulletin 210-40-4 - Sporlan Field Conversion of the Thermostatic Expansion Valves with Replaceable Thermostatic Elements Bulletin 210-60 - Sporlan Thermostatic Expansion Valves Identification SD-14 - Sporlan Thermostatic Expansion Valves Installation, Field Service, and Assembly SD-289 - Sporlan TEV Installation and InstructionsAdjustable beds are becoming increasingly popular as people look for ways to improve their sleep quality and comfort. With so many options available, it can be difficult to know wh...In this episode of the HVACR Distillery, Jamie shares some lesser-known tips on how to install, maintain, and set superheat on a TXV, or Thermostatic Expansi... Adjusting a sporlan txv, The Sporlan Type V thermostatic expansion valves have a cast bronze body, dual port semi-balanced design, flange connections, and inlet strainer. They are available with adjustable superheat, long lasting replaceable power element and accessible internal parts. Each valve is factory tested to ensure positive leak-free performance., The location of the equalizer line connection on the suction line has absolutely no relevance to whether the TEV has a bleed port or not. The equalizer has no special function with a TEV having a bleed port. So the bleed TXV will cost more than the Non-Bleed to operate in a day. P.S. WOW I got deep here., How do you adjust a sporlan txv valve As we discussed in an earlier podcast, a TXV is designed to maintain a specified and constant superheat at the evaporator coil outlet. It does this through a balance of forces between the bulb pressure (opening force), equalizer pressure (closing force), and spring pressure (closing force)., Type FX/FXC. TEV INSTALLATION INSTALACION DE VALVULAS DE EXPANSION TERMOSTATICA INSTALLATION DES TEV (THERMOSTATISCHES EXPANSIONSVENTIL) INSTALLATION DES DÉTENDEURS THERMOSTATIQUES INSTALLAZIONE DELLE VALVOLE D’ESPANSIONE TERMOSTATICHE INSTALAÇÃO DAS TEV (VÁLVULAS DE EXPANSÃO TERMOSTÁTICA) SD-414 / 42023. 0., The Sporlan Type CRO(T) crankcase pressure regulating valves have a brass body, extended copper connections, and inlet strainer. They are available with a range of adjustable settings and optional pressure tap, These valves automatically throttle the vapor flow from the evaporator, until the compressor can handle the load. ..., Adjustable beds are becoming increasingly popular as people look for ways to improve their sleep quality and comfort. An adjustable bed can provide a range of benefits, including i..., Sporlan - 168015 - TXV SQE BODY 3/8" x 1/2" x 1/4"ODF External Equalizer Angle . Parker Sporlan . Sporlan - 168015 - TXV SQE BODY 3/8" x 1/2" x 1/4"ODF External Equalizer Angle ... TXV/TEV - Thermostatic Expansion Valve: Outlet Connection Size: 1/2" ODF: Package Height: 6.25: Package Length: 14.5: Package Weight: 21.56: Package Width: 13: Prop ..., Sporlan 168198 - SBQE 3/8" x 1/2" ODF Cartridge Style Valve Body- The Sporlan Q and BQ series are replaceable cartridge style valves designed for small refrigeration systems, such as refrigerated cases, coolers, and freezers. The externally equalized versions of these valves are ideal for air conditioning and heat pump systems. BQ valves are balance ported, engineered specifically for systems ..., So... you’re six weeks into your new life in a new city. So... you’re six weeks into your new life in a new city. Or six months. Or a year. No matter how long it takes, at some poi..., If so you need to back that down to 15-20 degrees by removing some of the refrigerant. This is why your discharge pressure is so high. Also superheat of 28 degrees is starving the evaporator. Superheat should be 15-20 degrees at the compressor. Sporlan says to adjust the valve 1 rotation at a time., Sporlan largely solved this particular issue in the 40s when they brought the “balanced port” valve to market. While the technology is nothing new, it has been improved over time. Balanced port TXVs can vary in design, but they solve this problem by allowing the inlet pressure to affect the top and bottom of the needle (orifice) equally., 16. When adjusting a Sporlan TEV for 2° more superheat , how many turns of the adjustment stem are needed and in what direction? b. Clockwise (in) one half turn 17. How is the factory setting of the superheat adjustment determined on a Sporlan expansion valve? a. Find the mid-point of the superheat adjustment stem., equalized expansion valve is specifi ed, that particular evaporator used a refrigerant distributor and the net P across the distributor assumed was 25 psi for R-134a and 35 psi for R-22, R-404A and 507. If conditions differ from above, valve selections should be made from Sporlan Bulletins 10-9, 10-10 and 20-10., liquid-vapor mixture from the expansion valve. This ensures a dry vapor reaching the compressor. Oil return from the evaporator is also improved since the velocity in the evaporator is kept high by the hot gas. Sporlan 1650R Series Distributor or ASC –Two refrig-erant distribution methods are available to introduce hot gas in this manner: 1., The Sporlan Tech Check app provides a simple way to interface with the premier Sporlan S3C Case controller solution. The user will be able to view case parameters, process values, graph selected sensors, and allow temporary override of EEVs, EEPRs and solenoids. Contractors and technicians will be empowered to easily troubleshoot a case without ..., Bulletin 100-50-5.1 / 52020 Parker Hannifin Corporation Sporlan Division 206 Lange Drive, Washington, MO 63090 USA phone 636 239 1111 fax 636 239 9130 www.sporlan.com... View and Download Sporlan Superheat installation and operation instructions manual online. Superheat controller pdf manual download., Quick Reference Guide. SD-324/72016. Controller v. The Sporlan Superheat Control should be installed only by a qualified professional. All other system components (valves and sensors) should be supplied by Sporlan to ensure compatibility and proper operation. There are no user-serviceable components inside the con-troller., TXV Selector Tool Emerson is pleased to announce the launch of the TXV Selection Tool. This online sele ction tool allows user s to enter t heir HVACR system characteristics such as refrigerant type, temp eratures, pressure drop and capacity, and then selects the best Emerson thermal expansion valv es for the ..., I'm not sure that it does. I'm hearing a lot about not adjusting the TXV however I'm hearing a couple of guys that I trust say that if the SH is too high and suction is too low to go ahead and adjust it. Are the airflows correct, probably not, this unit is probably oversized for the duct., Unfortunately it is not compatible with other types of valves from sporlan. You'll need to replace it with the specific type of body. Sporlans outside of Q bodies can only have their powerheads replaced. Danfoss can have their cores replaced. If you got a bad "core" on a sporlan that isn't a Q body, then you gotta replace the whole thing., Connect the Electric Expansion Valve (EEV) wires to terminals 5, 6, 7, and 8. ... Sporlan Superheat Control Installation and Operation Manual ... and download Bulletin 100-50-5.1 3. OPERATION For further system tuning, adjust parameter setpoints as described below and in Bulletin 100-50-5.1. 1. Enter the Parameter Menu: Hold down the SELECT ..., Expansion Valve Parts Kit ; Kit Contains: 1 Seat, 1 Pin & Carrier, 2 Push Rods, 1 Seal Cap Gasket, 2 Flange Gaskets, 1 Bottom Gasket, & Form 38-14-692 ... For over 80 years Sporlan has set the industry standard for the development and manufacture of leading edge HVACR components. Brief content visible, double tap to read full content. ..., EMRSON Thermostatic Expansion Valves 0.79 A F K I C L B 3.07 0.63 59" D G H E M J TX7 Ordering Information Refrigerant Model Tons* Connection Size (in.) Cap Tube PCN R-410A R-32 TX7-Z16 20 7/8 x 1-1/8 ODF 5 FT 806816, Are you thinking about becoming a public adjuster? If so, you’ll need a specific skill set to succeed in this line of work as well as the right education. Keep reading to learn abo..., • The intended design life of the Electric Expansion Valve is 15 years, providing that the valve is installed and operated within the design intent, and the system is free from contaminants. ... • Sporlan is not responsible for any damage which may be caused by misuse or by installation of parts, accessories or controls which are not on the ..., www.sporlan.com recommended thermostatic elements application refrigerant thermostatic element system mop 22 134a 404a 407a 407c 407f 410a 448a 449a 507 513a psig air conditioning – x – – – – – – – – x kt-43-jcp60 50 x – – x x x – x x – – kt-43-vcp100 90 x – – x x x – x x – – kt-43-nga –, MAXIMUM PRESSURE (PSI): 700. ELEMENT: 45. The Sporlan Type R-ER-SR, and RC balance ported thermostatic expansion valves have a brass bar stock body. The R valve has flare connections, the ER has extended ODF connection and SR has extended ODF connections with forged inlet and replaceable strainer. Type RC valve contains an internal check valve., © Danfoss | DCS (az) | 2020.07 067R9608 067R9608 1 2 3 1 2 3 Danfoss 67B23.20 Superheat = t 1 - t s Danfoss 67B51.20 p s ~ t s Installation guide Thermostatic ..., SGE-1-GP 3X4 ODF 5'Thermostatic Expansion Valve - Sporlan - Type S, The thermostatic expansion valve (TEV) controls the flow of liquid refrigerant entering the direct expansion (DX) evaporator ... contact Sporlan Division of Parker. TEV CAPACITY RATINGS FOR REFRIGERANTS: 22, 134a, 401A, 402A, 404A, 407C, 408A, 409A, 410A, 422D, 507 7. Valve Nomenclature / Ordering Instructions, When you’re ready to adjust the TXV, remove the stem cap on the bottom to expose the spindle. It’s easy to make the adjustment if you make a mark at the edge of the spindle. That way, you can keep track of how many turns you make. Many manufacturers recommend turning the spindle only a quarter-turn at a time., My Sporlan TXV valve was installed in 1987 in my 3-4 ton Lennox Central Air Conditioner. The valve top is red-ornage colored and has the number "88" on its top. ... A fixed capillary tube does not adjust the amount of refrigerant it meters into the evaporator as does the TXV with the measuring of the temperature with the bulb. The correctly ..., Whether you’re a highly-skilled mechanic or just a repairman who fixes cars from their own garage or repair shop, you’re no stranger to having to do a repair or two. These repairs ...