Shopping locally can help small businesses and local economies thrive. Detroit Pistons, Corporate Sponsors Support Small Businesses Through Grants and Promotions. Shopping locally ...

4 ton 410a piston size. Manuals and buying guide for Comfortmaker - FEM4P3600A - Piston Air Handler R410A, 3 Ton, Copper Tube, Aluminum Fin Evaporator. Find specifications on Comfortmaker FEM4P3600A. Hotline Free: (888) 882-4424

Mar 19, 2017 ... Orifice along with the safety, efficiency, and service procedures involved. I compare 4 major points of difference and how they affect the ...

These units use R-410A refrigerant which operates at 50 to 70% higher pressures than R-22. Use only R-410A approved service equipment. Refrigerant cylinders are painted a “Rose” color to indicate the type of refrigerant and may contain a “dip” tube to allow for charging of liquid refrigerant into the sys-tem. CAUF4860C6 20" 28" 25" 4-5 ⅜" ⅞" .093 48 CAUF4860D6 23" 28" 25" 4-5 ⅜" ⅞" .093 39 CAUF4961C6 20" 28" 25" 4-5 ⅜" ⅞" .093 54 CAUF4961D6 23" 27" 25" 4-5 ⅜" ⅞" .093 59 * Shipped with Coil Note: For a properly matched system and piston sizing information, refer to Goodman piston kit chart of the corresponding Goodman® outdoor unit.Rheem RH1T4821STANJA - 4 Ton, R410A, Single Stage, Aluminum Air Handler, Constant Torque Motor, 208/240V, 1 Ph, 60 Hz: Item Number: RH1T4821STANJA: Manufacturer Product Number: ... Drain Connection Size: 3/4" Suction Line Fitting: Sweat or Braze: Suction Line Size (OD) 7/8" Liquid Line Fitting: Sweat or Braze: Liquid Line Size (OD) …4 to 5 ton evaporator coil. Installable in the horizontal configuration. Usable with either a heat pump or an AC-only condenser. Works with R410A or R22 refrigerant. Low air leakage. Check flowrater expansion device for use in any application. 4 to 5 Tons. At an output of 4 to 5 tons, the Goodman CHPF4860D6 evaporator coil is ready for almost ...Goodman 4 - 5 Ton, Cased Evaporator Coil (W 24-1/2 x D 21 x H 30) - Cased TXV Included. SKU: CAPT4961D4 Goodman100000042 ADP Piston - size 76 R410A (4 Ton) Abrpn: 100000042. Your No. This is non stock item. More Information. SKU. 104214. Default UOM.ADP 100000036 - Piston .53, 1 1/2 Ton R22, 2 Ton R410APiston Size 53. Can be used on 1 1/2 Ton R22 Coil or 2 Ton R410a Coil.NO WARRANTY CLAIM WILL BE HONORED FOR MIX-MATCHED SYSTEMS THAT FAIL TO ADHERE TO THE SPECIFIED PISTON SIZE. WARNING Indoor Unit Indoor Piston Size Piston P/N Note TXV Kit P/N (if used) Outdoor Unit GSX140421A* ASX140421(C,D)* SSX140421(B,C)* All AHRI Matches 0.070 B1789870 TX5N4 1,3 ANX140421A* All AHRI Matches 0.074 B1789874 TX5N4 1,3

ADP 100000042 - Piston .76, 4 Ton R410APiston Size 76. Can be used on 4 Ton R410a Coil.20-ton product line has been designed for use only with R-410A and POE oil (check unit model number for specific refrigerant). R-410A is a high-pressure refrigerant that …piston kit chart 4 pkcg-4001u april 2018 (*) signifies unit revision. (1) correct piston is supplied with the outdoor unit. (2) correct piston is supplied in the highest sales volume tested combination indoor unit. all other indoor combinations, piston must be purchased from distributor. (3) txv must be purchased separately.Hello, The cased "A" coil is a Model # TXCO49C4HPCO S/N Z0522LH5G made by American Standard. The 5 Ton condensor is made by Trane and it is Model # 2TTR1060A1000AA and S/N 5311T292F. I did remove the uncased coil from my air handler unit. It was in a housing that was mounted in front of the air handler. outdoor goodman indoor piston outdoor goodman indoor piston section indoor piston kit section indoor piston kit coil btu's size part no. coil btu's size part no. ckl18-1 18000 .052 (2) clj36-1 36000 .071 (2) 24000 .059 to .052 b17898-52 (3) 42000 .078 to .073 b17898-73 (1) 29000 .059 to .052 b17898-52 (3) 47000 .082 to .073 b17898-73 (1)

Is your A/C System in need of repair or service? Get connected with the best heating and air conditioning contractors in your area. Call an AC Pro Certified contractor today for all HVAC services. Effective 4/1/10. Subject to change without notice. R22 (F) R410A (G) ... 3.5T 0.080 3990 0.074 4001 4T 0.084 3991 0.080 3990 5T 0.092 3998 0.089 3960 Table 1: Piston Size- Non TXV use NOTE TO THE INSTALLER: These instructions are for the use of qualified individuals trained and experienced ... for R-410a and green for R-22) to assist with ...a. Exceptions for air conditioning (cooling only) applications, 1/4" liquid line may be used in: i. 1.5 ton applications for up to 100 equivalent feet (30.5 equivalent meters) with maximum 40’ (12.2 m) vertical lift ii. 2.0 ton applications for up to 75 equivalent feet (22.9 equivalent meters) with maximum 20’ (6.1 m) vertical lift b.Commercial 27.5 to 50 ton 60 hz, 22.9 to 41.7 ton 50 hz cv or vav rooftop air conditioners with reliatel controls, r-410a refrigerant (152 pages) Air Conditioner Trane Voyager YS 150–300 Installation, Operation And Maintenance Manual. ... See Table 1 for factory installed piston size. Some system combinations will require a different sized ... *Piston size needed for system combination may not be pre-installed. See Table 1 for pre-installed size. **Necessary piston size varies for this tonnage. See Table 3. Table 3. R410a piston sizes for 2.5T outdoor capacity system. Piston Unit Model* Coil Model Size (R410a) 4MXCA001AC6HCA 0.052 factory installed 4MXCB002AC6HCA 0.052 factory installed These units use R-410A refrigerant which operates at 50 to 70% higher pressures than R-22. Use only R-410A approved service equipment. Refrigerant cylinders are painted a “Rose” color to indicate the type of refrigerant and may contain a “dip” tube to allow for charging of liquid refrigerant into the sys-tem.

Craigslist dayton tn houses for rent.

The YORK® LX Series YC2D 13.4 SEER2 Single-stage Air Conditioner provides reliable operation that meets your needs and fits your budget. With robust compressor technology that's been proven in our extreme, accelerated-wear test facility, its compact cabinet fits advanced performance in less space. A direct-drive fan design minimizes vibration ...4 Ton*. 22.5". 3 Ton. 16.5". PROTECTION. ADP is the ... 1: Piston (R-410A). 2: Piston (R-22). 6: Non-bleed A/C ... Piston Size [3]. AP: TXV access port [4]. MBTUH R ...These units use R-410A refrigerant which operates at 50 to 70% higher pressures than R-22. Use only R-410A approved service equipment. Refrigerant ... 2.1 Unit Dimensions and Weight 2.2 Refrigerant Piping Limits Table 2.1 When mounting the outdoor unit on a roof, beAs the efficiency goes up pressure difference drops. 410 carries more BTU's /LB than 22. When you add all those up it could come out the same. In other words it takes a certain size orifice to move X lb of R-22 equal to Y BTU and that same size orifice just happens to move the right amount of R-410a because the efficiency of the system creates ...

Insulated air handler blower & coil compartments. Condenser pre-charged with R410A refrigerant. Suitable for use in manufactured & mobile homes. Integrated Horizontal Drain pans and metal Vertical Drain. Specifications. Condenser Dimensions: H38 1/5" x W30 1/5" x D30 1/5". Air Handler Dimensions: H54 1/2" x W22" x D24".The 410 pistons are smaller than 22. I assumed it was because the pressure on 410 is higher. You have to make sure you change them especially if your dealing with a 2 1/2 or 3 1/2 ton system. The coil is equipped with the right piston for freon. For example a 3 1/2 ton takes a 73 piston but a 4 ton coil comes with a 84.Traffic alone doesn't pay the bills. You need conversions. A squeeze page can help you generate conversions and build your email list. Here's how... Trusted by business builders [email protected]. (888) 601–0038. Follow Us. General Features:The M4AC40 is fully charged from the factory. This unit is designed to operate at outdoor ambient temperatures as high as 115 °F. Cooling capacities are matched with air handlers and furnace coils that are AHRI certified. The unit is cert.First time central anything has ever been in this house. (Window units suck a** noise wise and I'm loving the quiet now) Evaporator ICP FSM4P2400A (1) 2 ton R410a unit with a size .057 piston installed Condenser ICP N4A324GKC100 2ton R410a unit with a size .055 piston supplied (in an accessory bag) that was not installed in place of the .057 ...*.Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. 3/4 3/4 3/4 7/8 7/8 7/8 1-1/8 Max Liquid Line† †.See Liquid Line Sizing For Cooling Only Systems with R-410A Refrigerant tables. 3/8 OUTDOOR UNIT SIZE FAN COIL PISTON SIZE BY OUTDOOR …4 - R-410A only. P. Cased - Painted. 6 - R-22 or R ... ¹ (ft²). ² Shipped with Coil. Note: For a properly matched system and piston sizing information, refer to ...ADP 100000042 - Piston .76, 4 Ton R410APiston Size 76. Can be used on 4 Ton R410a Coil.INSTALLATION INSTRUCTIONS R−410A Split System Air Conditioner 4 421 01 5103 00 UNIT SUPPORT NOTE: Unit must be level ... Check piston size shipped with indoor unit to see if it ... FEM4P, FSM4P, FSU4P (12 thru 4 ton). See Figure 4. When changing indoor piston, use a back−up wrench. Hand tighten hex nut, then tighten with wrench 1/2 turn. …Jan 7, 2014 ... Do not try this at home! HVAC training is required. Town & Country Air, Inc. serves the greater Wilmington, NC area including New Hanover, ...I have a 1991 Rheem 2.5 ton A/C and coil. Last summer, it lost all 4 lbs of R-22. I've got several proposals for replacing it with a new compressor and coil using R-410a. All the proposals specify reuse of the existing 3/4" and 3/8" lineset. The suction line has a severe bend, almost to the point of being crimped, just before it enters the outdoor unit …

ADP 100000039 - Piston .67, 2 1/2 Ton R22, 3 Ton R410APiston Size 67. Can be used on 2 1/2 Ton R22 Coil or 3 Ton R410a Coil. The store will not work correctly in the case when cookies are disabled. Due to scheduled maintenance, some website features will be unavailable on Saturday 10/29. ...

At 236,857 tons, Wonder of the Seas will be nearly 4% bigger than the current size leader in the cruise world, Royal Caribbean's 3-year-old Symphony of the Seas The first voyages o...The range on flow rater piston of Goodman 2.5 ton condenser is from .059 to a .078 . Now if you needed a .059 and you put a .078 in it. It can flood back to get the compessor, also. Then vise versa it will starve the evaperator. You need to get the condenser model number and match it up to the evaperator coil model number or your …Unless you want to mismatch, why not just get a Rheem, Ruud or WeatherKing outdoor unit that is designed for that coil. WeatherKing is the economy model but still has a full metal jacket and scroll compressor in 4 ton. The 82 piston is for 4 ton, a 3.5 ton will come with a 73 piston to put in the RCBA-48 coil.ADP 100000042 - Piston .76, 4 Ton R410APiston Size 76. Can be used on 4 Ton R410a Coil.Brand New HEIL 2.5 Ton R-410A Piston Air Handler Multi-Position Aluminum 208/230/1 Model# FEM4P3000AL #BSP1 ... Refrigerant Type R-410A Liquid Line Size 3/8 in Suction Line Size 3/4 in Filter Size 16-3/8 x 21-1/2 in Motor Type ECM Motor Rating 1/3 hp Dimensions 49-5/8 in H x 17-5/8 in W x 22-1/16 in D ...I was thinking R22 & 3.5- 13 SEER and I am working on 4.0 - 14 SEER -R410a - That is where I screwed up! Thinking R22. Piston chart for R410A- …NO WARRANTY CLAIM WILL BE HONORED FOR MIX-MATCHED SYSTEMS THAT FAIL TO ADHERE TO THE SPECIFIED PISTON SIZE. WARNING Indoor Unit Indoor Piston Size Piston P/N Note TXV Kit P/N (if used) Outdoor Unit GSX140421A* ASX140421(C,D)* SSX140421(B,C)* All AHRI Matches 0.070 B1789870 TX5N4 1,3 ANX140421A* All AHRI Matches 0.074 B1789874 TX5N4 1,3Product Description. Features. 10 year warranty on parts & compressor High efficiency scroll compressor. Direct drive multi-speed PSC indoor motor. All aluminum evaporator coil Designed for upflow, downflow, horizontal left and horizontal right installations. Condenser pre-charged with R-410A refrigerant. Insulated air handler cabinet.3.5 Ton, 4 Ton : Product Width (in) 17.5 : Line Set Connection Type: Sweat : Liquid Line Size: 3/8 inch : Weight (lbs) 66.000000 : Refrigerant: R-410a : Suction Line Size: 7/8 inch : Warranty: 5 Year Parts, 10 Year Evaporator Coil: California Residents: see Prop 65 WARNING

Wordle hint jan 1.

Ciocca ford lincoln of flemington.

Qty. $239.00. Diversitech 3/8" Sight Glass Sweat for Air Conditioner Condenser View Item. Add To Cart. Qty. $32.95. The Goodman GSXN3N2410 is a 2 ton cooling-only condenser unit. Providing a 13.4 SEER2 efficiency with a single stage, reciprocating compressor, the GSXN3N2410 is an inexpensive condenser to cool your home when paired with an AC coil. FEM4P4800AL - 4 Ton, R410A, Multi-position ECM Motor Fan Coil, With Piston, Aluminum Tubes, Aluminum Fin . About. About Gemaire; About Heating And Cooling Supply ... Maximum Fuse Size: 15: Metering Device: Piston or Flowrator - Fixed Metering Device: Nominal Electric Heat (kW) 3-30: Number of Speeds: 5 (Five) OPT Code: … Johnson Controls Ducted Systems Technical Guide: R-410A Outdoor Split-System Heat Pump - RHP143 York International Corporation, 5005 York Drive, Norman, OK 73069 Effective 4/1/10. Subject to change without notice. R22 (F) R410A (G) Tonnage Orifice Sz PART # Orifice Sz PART # 1.5T 0.055 3999 0.049 4006 2T 0.059 4000 0.055 3999 2.5T 0.068 3987 0.059 4000 3T 0.074 4001 0.068 3987 3.5T 0.080 3990 0.074 4001 4T 0.084 3991 0.080 3990 5T 0.092 3998 0.089 3960 Table 1: Piston Size- Non TXV use [email protected]. (888) 601–0038. Follow Us. ADP 100000041 - Piston .73, 3 Ton R22, 3 1/2 Ton R410APiston Size 73. Can be used on 3 Ton R22 Coil or 3 1/2 Ton R410a Coil.Heat Pumps /. Performance 4-Ton 14 SEER R410A Heat Pump (460 V 3-Phase) Need help with your order? We have the depth of experience and inventoried stock plus technical support to handle your job from the smallest to the largest! 781-322-8800. outdoor goodman indoor piston outdoor goodman indoor piston section indoor piston kit section indoor piston kit coil btu's size part no. coil btu's size part no. ckl18-1 18000 .052 (2) clj36-1 36000 .071 (2) 24000 .059 to .052 b17898-52 (3) 42000 .078 to .073 b17898-73 (1) 29000 .059 to .052 b17898-52 (3) 47000 .082 to .073 b17898-73 (1) Goodman Piston Coil Chart. Johnstone Supply is a leading wholesale distributor for HVACR equipment, parts and supplies available and in-stock at local branches.1048A16C 4 TON R22 CASED COIL 17.5" W/R410A PISTON. Sku#: 116614. Details. Air Conditioner Evaporator Coil; Item Coil; Size 17-1/2 Inch x 21-1/4 Inch x 20 Inch; Material Copper Alloy (Tubing); Used On Item Air Conditioner; Pressure Rating 2490 PSI; Refrigerant Type R-22; Coil Size 4 Ton. SPECIFICATIONS.I work at a University, and am fighting a reoccurring issue with a residential split system not keeping up when temps get into the mid 80's and up. Unit is a 3 ton R410 I.C.P. unit, fixed orifice. Indoor unit calls for a 070 piston. This piston in it is 067. Condenser only references TXV, doesn't specify a piston size. Subcool is approx 10, … ….

These units use R-410A refrigerant which operates at 50 to 70% higher pressures than R-22. Use only R-410A approved service equipment. Refrigerant cylinders are painted a “Rose” color to indicate the type of refrigerant and may contain a “dip” tube to allow for charging of liquid refrigerant into the sys-tem. 3. Remove the piston from the mechanical fitting in liquid line. Remove and discard the O-ring. NOTE: Remove the piston. 4. Install new O-ring on fitting. O-ring is supplied in kit. 5. Using a back-up wrench, reattach the fittings. Tighten until bodies “bottom” or a definite resistance is felt. The valve will only fit in one direction of flow.Nominal Capacity 2.5 ton. Flow Rate 1000 cfm. Power Source 208/230/1. Refrigerant Type R-410A. Liquid Line Size 3/8 in. Suction Line Size 3/4 in. Filter Size 16-3/8 x 21-1/2 in. Motor Type ECM. Motor Rating 1/3 hp. Dimensions 49-5/8 in H x 17-5/8 in W x 22-1/16 in D. Metering Device Piston4 ton 410a what size piston do I need to put in the air handler coil? The new condenser did not come with a piston 4 ton air handler 4 ton condenser. PHM-----Faced with the choice between changing one's mind and proving that there is no need to do so, almost everybody gets busy on the proof.Typical low pressure or suction side pressure for R410A is about 120 psi, varying by ambient temperature, here assuming 75°F, may vary by equipment and metering controls. 3. Typical high side pressure for R410A is < 600 psi at an ambient outdoor temperature of 95 °F, may vary by equipment. 4.May 13, 2014 · I just had a new condenser and evaporator installed, a Goodman model GSX130481BC 4 ton condenser and 4-5 ton Goodman model CHPF4860D6DB coil using R410A. The day after install, the system produced about a 14 degree F drop between the air intake and outlet vents. Check piston size shipped with indoor unit to see if it matches required indoor piston size. If it does not match, replace indoor piston with correct piston size in table below:First time central anything has ever been in this house. (Window units suck a** noise wise and I'm loving the quiet now) Evaporator ICP FSM4P2400A (1) 2 ton R410a unit with a size .057 piston installed Condenser ICP N4A324GKC100 2ton R410a unit with a size .055 piston supplied (in an accessory bag) that was not installed in place of the .057 ... 4 ton 410a piston size, 2.5 Ton Oxbox by Trane R410A Multi-Position Standard Efficiency Air Handler. Home / Featured Brands / Oxbox by Trane / 2.5 Ton Oxbox by Trane R410A Multi-Position Standard Efficiency Air Handler. $ 1,222.41 – $ 1,739.41. Buy in monthly payments with Affirm on orders over $50. Learn more., The amount of material a dump truck holds depends on the size of the dump truck, and the type of material dictates the number of tons. For example, a cubic yard of sand weighs 2.2 ..., Is your A/C System in need of repair or service? Get connected with the best heating and air conditioning contractors in your area. Call an AC Pro Certified contractor today for all HVAC services., Buy Goodman B1789857 2 Ton Orifice Kit for R-410A, 14 SEER Air Conditioner. Goodman technical support information, product brochures and more. Place Your Order by 1 pm for Same-Day Shipping, A 0.067 orifice is about right for a 3 ton 13SEER R-410A system, or at least really close, depending on which manufacturers chart you look at. Generally you should ignore the orifice size listed on the indoor coil, and go with what the outdoor unit calls for, which in this case is a TXV., Capillary Tube Length (in.) 17.810 (1). Inside Diameter (in.) .095 (1). Number of Capillary Tubes. 6 (4); 3 (2); 2 (1). Orifice Diameter (in.)., Is your A/C System in need of repair or service? Get connected with the best heating and air conditioning contractors in your area. Call an AC Pro Certified contractor today for all HVAC services., 3. Remove the piston from the mechanical fitting in liquid line. Remove and discard the O-ring. NOTE: Remove the piston. 4. Install new O-ring on fitting. O-ring is supplied in kit. 5. Using a back-up wrench, reattach the fittings. Tighten until bodies “bottom” or a definite resistance is felt. The valve will only fit in one direction of flow., 4 ton 410a what size piston do I need to put in the air handler coil? The new condenser did not come with a piston 4 ton air handler 4 ton condenser. PHM-----, piston kit chart 4 pkcg-4001u april 2018 (*) signifies unit revision. (1) correct piston is supplied with the outdoor unit. (2) correct piston is supplied in the highest sales volume tested combination indoor unit. all other indoor combinations, piston must be purchased from distributor. (3) txv must be purchased separately., According to Capital Home Builders, a 2,300-square-foot home needs a 4-ton air conditioner. Since there are 12,000 BTUs per ton, a house of this size needs a 48,000-BTU air conditi..., TX2N4A Non-bleed Valve AC or HP R-410A 1½ - 2 Ton TX3N4 Non-bleed Valve AC or HP R-410A 2½ - 3 Ton TX5N4 Non-bleed Valve AC or HP R-410A 3½ - 5 Ton Downflow Insulation Kit ... For a properly matched system and piston sizing information, refer to Amana piston kit chart of the corresponding Amana® outdoor unit. Minimum Circuit …, Lennox Elite C35, C35-49C-2, 4 Ton, Piston (R410A), Uncased Aluminum Upflow Evaporator Coil. Cat # : 16F44. Model/Part # : C35-49C-2. Replacement Available This product has been replaced by Cat# ... 4 Ton . Metering Device. Piston (R410A) Product Depth. 21.5 Inch . Product Width. 19.5 Inch . Product Height. 28.5 Inch . Cased. …, Cabinet Finish 4 - R-410A only U Uncased P Cased - Painted C Cased - Unpainted Expansion Device Nominal Width or f Gas Furnace F Flowrater A - 14” Width D - 24.5” Width ... Tons Connection Piston Size* (in.) Ship Weight W H A Liquid Suction (lbs) CAUF3137B6 16½" 27" 25" 2½-3 ⅜" ¾" .071 53, Mortex coils for manufactured housing are universal R22/R410a. The metering device (piston or TXV) is the key. It is common to replace a R22 condenser with a R410a condenser, keep the evap coil and change piston or TXV to match. The SEER on these suck when new. Disclaimer, I will only change out a manufactured house system if coil and condenser ..., Factory supplied charge R-410A; Glossy corrosion resistant finish; High pressure switch; ... Silver Series 3 Ton, 14 SEER, R410A, Air Conditioner Unit, 208-230/1/60: Item Number: 4A7A4036L1000A: ... Drain Connection Size: 3/4" Suction Line Fitting: Sweat or Braze: Suction Line Size (OD) 3/4" Liquid Line Fitting:, iPad: There are apps that are great for writing and then there are apps that great for editing. The recently updated Phraseology does both, but it really excels when you start edit..., Goodman Piston Coil Chart. Johnstone Supply is a leading wholesale distributor for HVACR equipment, parts and supplies available and in-stock at local branches. , Residential Fan Coil; with standard features:ENVIRONMENTALLY SOUND R-410A SYSTEMSFactory installed piston metering device with Teflon ringHigh efficiency ECM, 5-speed motorCopper tube/aluminum fin coil on standard modelsAvailable with industry exclusive t , Effective 4/1/10. Subject to change without notice. R22 (F) R410A (G) Tonnage Orifice Sz PART # Orifice Sz PART # 1.5T 0.055 3999 0.049 4006 2T 0.059 4000 0.055 3999 2.5T 0.068 3987 0.059 4000 3T 0.074 4001 0.068 3987 3.5T 0.080 3990 0.074 4001 4T 0.084 3991 0.080 3990 5T 0.092 3998 0.089 3960 Table 1: Piston Size- Non TXV use, Wrong piston size for 15 year unit never ran right from the date of install www.amazon.com/shop/miheatingguyMilwaukee 2131-20 M18 ROCKET Dual Power Tower Lig..., Refrigeration Type. R-410A. Cooling Efficiency (EER) UP TO 10.85. Phase. 3. Capacity Range (BTU) 37200-83000. Voltage@Hz., [email protected]. (888) 601–0038. Follow Us. Learn more. ADP 100000042 - Piston .76, 4 Ton R410APiston Size 76. Can be used on 4 Ton R410a Coil. , Effective 4/1/10. Subject to change without notice. R22 (F) R410A (G) Tonnage Orifice Sz PART # Orifice Sz PART # 1.5T 0.055 3999 0.049 4006 2T 0.059 4000 0.055 3999 2.5T 0.068 3987 0.059 4000 3T 0.074 4001 0.068 3987 3.5T 0.080 3990 0.074 4001 4T 0.084 3991 0.080 3990 5T 0.092 3998 0.089 3960 Table 1: Piston Size- Non TXV use , Wrong piston size for 15 year unit never ran right from the date of install www.amazon.com/shop/miheatingguyMilwaukee 2131-20 M18 ROCKET Dual Power Tower Lig..., Duct, Registers and Grilles. Electrical Supplies. Fuel Oil Systems, R-410A 2 Ton; R-22 1.5 Ton; Piston Size 53; Specifications Product Name: Piston #53 2T R410A Brand Name: ADP Item # 100000036 Weight: 1 lbs Length: 12 in Width:, NO WARRANTY CLAIM WILL BE HONORED FOR MIX-MATCHED SYSTEMS THAT FAIL TO ADHERE TO THE SPECIFIED PISTON SIZE. WARNING Indoor Unit Indoor Piston …, RA1430AJ1NA Classic® Series 2 1/2 ton 14 SEER Single-Stage Air Conditioner-208/230/1/60 RA1436AJ1NA Classic® Series 3 ton 14 SEER Single-Stage Air Conditioner-208/230/1/60 RA1442BJ1NA Classic® Series 3 1/2 ton 14 SEER Single-Stage Air Conditioner-208/230/1/60 RA1448AJ1NA Classic® Series 4 ton 14 SEER Single-Stage …, This manual is also suitable for: View and Download Daikin R-410A technical data manual online. Outdoor units. R-410A air conditioner pdf manual download. Also for: Rxs-g2v1b., Email a Friend. 888-341-7330. FIXED ORIFICE PISTON - R22 2.0T & R410A 2.5T - .059 OPENING - B1789859. , Nominal Capacity 2.5 ton. Flow Rate 1000 cfm. Power Source 208/230/1. Refrigerant Type R-410A. Liquid Line Size 3/8 in. Suction Line Size 3/4 in. Filter Size 16-3/8 x 21-1/2 in. Motor Type ECM. Motor Rating 1/3 hp. Dimensions 49-5/8 in H x 17-5/8 in W x 22-1/16 in D. Metering Device Piston, 048 = 4 Tons ... Check piston size shipped with indoor unit to see if it matches required indoor piston size. ... Table 4 – AC with R-410A Refrigerant Long Line ...